28
PERFECTA-T
SATEL
Triggering timers
[44.Timers]
– the output control timers (starting the timer activates the
output). The parameter refers to the 15. C
ONTROLLED
output.
Fig. 14. “Outputs” tab.
7.3 Quick control of outputs
If the quick control of the outputs 15. C
ONTROLLED
is to be available in keypads, the outputs
of this type must be assigned to the corresponding keypad keys. One output can be assigned
to each number key.
7.4 Wireless siren
PERFECTA-T 32-WRL
If a wireless siren is assigned to the output, additional parameters and options are available
(outputs 13-16).
Filter
[1272.Filter]
– time counted from the moment of receiving transmission from the siren.
After it has elapsed and no other transmission is received, trouble will be reported.
Signaling
[1275.Al.signal.]
– alarm signaling mode.
Arm/Disarm beep
[1276.Acknowled.]
– signaling mode for arming/disarming etc. (cf.
A
RM
/D
ISARM
/
CLEAR SIGN
. option).
Tamp. in part.
[1274.Out.tamper]
– partition in which alarm will be triggered in the event of
siren tamper.
8. Communication
Panel key
[01.PERFECTA key]
– identifier of the alarm control panel. You can enter up to 16
alphanumeric characters (digits, letters and special characters). You can enter spaces, but
at least one character must be different from the space. Do not program the same key for
different control panels. Communication between the PERFECTA
S
OFT
program and the
control panel is only possible, when the program key and the control panel key are
identical.
For the control panel with factory default settings, the PERFECTA
S
OFT
program will
generate a random key that must be written to the control panel.