6
INT-SK
SATEL
NC
[Normal.closed NC] – the relay contacts are closed (they open on activating the relay).
Authorization
control
[Unauth. event] – if this option is enabled, unauthorized opening of
the door will save the event to the control panel memory.
Alarm on unauth. access
[Unauth. alarm] – if this option is enabled, unauthorized opening
of the door when the partition is armed will trigger an alarm. The option is available if the
“Authorization control” option is enabled.
Max. door open time
[Max. door open] – the maximum period of time during which the door
can be open (the door status input can be disconnected from common ground). If the door
is open longer, audible alarm will be triggered in the keypad, and the event will be saved to
the control panel memory. You can enter from the 0 to 255 seconds. If you enter 0, the
door can be open for any long period of time.
Dependent on door (1)
/
Dependent on door (2)
– you can select the door that must be
closed so that the user can get access (turn the relay output on). It allows you to create an
airlock. You may select a door supervised by another expander or alarm system zone
programmed as type “57 Technical – door open”.
Confirmation
– method of providing feedback to the user after using the keypad:
No
– no feedback.
Sound
– the keypad will use sounds to give feedback to the user.
Backlight
– the keypad will use key backlight to give feedback to the user.
Code+* do not disarm
[Code* not dis.] – if this option is enabled, entering the code and
pressing
will not disarm the partition (to disarm the partition, the user must enter the
code and press
).
Access if armed
[Code* in arm] – if the option is enabled, the users can gain access (turn
the relay output on) when the partition is armed. If the option is disabled, the users cannot
gain access when the partition is armed. The option is available, if the “Code+* do not
disarm” option is enabled. The option does not apply to the “ON if partition armed” mode.
Users
[Master users / Users] – the administrators and users which are permitted to use the
keypad.
FIRE alarm
– if this option is enabled, pressing and holding
for 3 seconds will trigger
the fire alarm.
AUX. alarm
[Medical alarm] – if this option is enabled, pressing and holding
for 3
seconds will trigger the medical alarm.
PANIC
alarm
– if this option is enabled, pressing and holding
for 3 seconds will trigger
the panic alarm.
silent
[Silent panic] – if this option is enabled, the panic alarm triggered from the keypad will
be a silent one, i.e. the keypad will not indicate it, there will be no audible signal, but the
alarm will be reported to the monitoring station. The silent panic alarm is useful when the
control panel is sending events to the monitoring station, but unauthorized persons should
not be aware of the alarm being triggered. This option is available, if the “PANIC alarm”
option is enabled.
Alarm 3 incorrect codes
[3 wrong codes] – if this option is enabled, entering a wrong code
three times will trigger an alarm.
Quick arming
[Quick arm] – if this option is enabled, the user needs no code to arm the
partition using the keypad.
Control “BI”
output
[BI outs ctrl.] – if this option is enabled, the ““Bi” output operating” type
of users can use the keypad to control outputs.
Control “MONO” output
[MONO outs ctr.] – if this option is enabled, the ““Mono” output
operating” type of users can use the keypad to control outputs.