5.  Operation in the Partition Keypad Mode 

The LEDs show following information: 

 

off when alarm is cleared. 

ALARM

 (red color) – steady light indicates an alarm in the

blinking indicates that an alarm was triggered in the partitio

 keypad controlled partition, while 

n (alarm memory). The LED goes 

 

ARMED 

(green color) – steady light indicates that the partition to which the keypad is assigned 

has been armed. Blinking indicates countdown of the exit delay. 

 

TROUBLE

 (yellow color) – blinking indicates that a technical problem has occurred. 

e LCD keypad. Arming the 

Note: 

Informa

keypad can be found in the user manuals of the control panels. 

ICE MODE

 

 

Lo

 in the LCD keypad – its activation provides access to the 

Lock 

Lo

X

)/

Lock feature

 (

D

LOAD

64

) – its activation provides access to the lock feature options. 

ac

vice (e.g. electromagnetic door lock) 

by 

means of the partition keypad.

 This 

 entering the CODE and pressing the 

The signaling applies to troubles from the entire alarm system, not only from the keypad 
controlled partition. The type of trouble can be checked on th
keypad controlled partition will disable the trouble signaling. Disarming the partition will 
restore the trouble signaling. 

All LEDs may be OFF in the arming mode, depending on the control panel settings. 

tion on the use of the partition 

The partition keypad can be programmed by means of the LCD keypad (

S

ERV

S

 

H

 

E

 

S

 

expander selection

) or a computer with

TRUCTURE

ARDWARE

XPANDERS

ETTINGS

the 

D

LOAD

X

/

D

LOAD

64 

program. Described below are settings and options available for programming 

Abbreviations from the LCD keypad display are shown at some of the functions. 

Name 

– option to give an individual (16-character) name to the module. This option can be accessed 

in the LCD keypad as follows: 

S

ERVICE MODE

 

S

TRUCTURE

 

H

ARDWARE 

E

XPANDERS

 

N

AMES

 

expander selection

Partition 

– assignment of the keypad to a partition selected from the list. The keypad controls this 

partition. 

ck feature 

– the option available

submenu. 

ck

 (

D

LOAD

The options „Lock feature” (LCD / DLOAD64) and „Lock” (DLOADX) refer to support of the 

tuating de

function is made available to any user authorized to use the keypad (see: 

M

ASTER USERS

/U

SERS

 

function). Control is effected by means of the relay. 

Lock features 

(

D

LOAD

X

)

/Lock

 (

D

LOAD

64

)

 

ON if partition armed

 – the relay is active when the partition is armed, and inactive when the 

partition is disarmed. 

Note:  When operating in this mode the relay will change its state automatically, if the partition is 

disarmed from the given keypad. When the partition is disarmed from another keypad, 
the state of the relay will change on

 key on the 

Fixed O

given partition keypad. 

N time 

[ON time] – after the user enters the CODE and presses the 

 key, the relay will 

ctive for the R

ELAY 

ON

 TIME

be a

Fixed ON time – OFF if door open

 [ON, open

off] – after the user enters the CODE and presses 

the 

  key, the relay will be active until the door is opened (the door st us control input is 

isolated from the common ground

at

), however not longer than for the 

R

ELAY 

ON

 TIME

Fixed ON time – OFF if door closed

 [ON, close

off] – after the user enters the CODE and 

presses the 

 key, the relay will be active until the door is closed (the door status control input 

is shorted again to the common ground), however not longer than for the 

R

ELAY 

ON

 TIME

Re

be

 s

lay ON time

 – the time period during which the relay is active. Duration of the „relay ON time” can 

 from 

1

 to 

255

econds. 

Содержание INT-SCR-BL

Страница 1: ...f the delay in the partition for the zones with reaction type 3 INTERIOR DELAYED The time period during which these zones will act as delayed ones is programmable for the keypad After expiry of the pr...

Страница 2: ...erminals of the expander bus on the control panel PCB 5 Connect the door status control detector to the brown and blue cables If the door status is not to be controlled connect the brown cable to the...

Страница 3: ...d the LED designated ARMED will start blinking 6 Select the operating mode by pressing in turn and partition keypad with proximity card reader INT SCR and entry keypad INT ENT and partition keypad INT...

Страница 4: ...e shown at some of the functions Name option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows SERVICE MODE STRUCTURE HARDWARE EXPANDERS NA...

Страница 5: ...enabled ster users Users this function defines master users users authorized to use the given keypad Alarms FIRE a key triggers the fire alarm e AUX alarm pressing and holding down for approx 3 secon...

Страница 6: ...anel and the partition keypad user No the keypad provides no information on execution of or refusal to execute an operation Sound the keypad provides information on execution of or refusal to execute...

Страница 7: ...a computer with the DLOADX program Described below are settings and options available for programming Name option to give an individual 16 character name to the module This option can be accessed in t...

Страница 8: ...code is entered or the card is read in After expiry of the programmed time the interior delayed zones will again act as instant ones unless the partition is disarmed No auto reset after 3 tampers you...

Отзывы: