SATEL INT-RX-S 

  LCD keyfob – use C

OPY 

R

K

EYFOBS

 function (service mode 

S

TRUCTURE

 

H

ARDWARE

 

E

XPANDERS

 

C

OPY 

R

K

EYFOBS

). 

Using the keyfob, the user can control up to 6 zones of the alarm system. These zones should not 
exist physically and the wiring type programmed for them must be different from N

O DETECTOR

 and 

F

OLLOW OUTPUT

. You can select any type for these zones. Pressing a keyfob button(s) will violate the 

zone. 
To manage the keyfobs, you can use a keypad (refer to the control panel user manual) or the 
DLOADX program. 

4.1  433 MHz keyfob management using the DLOADX program 

You can manage the keyfobs in the “Keyfobs INT-RX” window. The window opening command is 
available in the "Users" menu. Before making any changes, click on the “Read” button, and after 
making the changes – on the “Write” button (the data related to keyfobs are not read and saved after 

clicking on the 

 in the program main menu). 

Notes: 

 

Removing a keyfob only clears its serial number, but not its settings. If a new keyfob is added to 
the user, it will have the same settings as the removed one. 

 

You can delete all keyfobs, including their settings, using the R

EM

.

 

RX

 KEY FOBS

 function, 

available in the keypad service mode (

S

TRUCTURE 

H

ARDWARE 

E

XPANDERS 

R

EM

.

 

RX

 KEY 

FOBS

). 

Adding a 433 MHz keyfob by means of the 

D

LOAD

X

 program 

Entering the serial number manually 

1.  Click on the field in the "S/N" column next to the name of the user to whom you want to assign a 

keyfob. 

2.  Enter the keyfob serial number and press ENTER. 

Reading the serial number during transmission 

1.  Click on the field in the "S/N" column next to the name of the user to whom you want to assign a 

keyfob. 

2.  Click on the "New" button. The "New" window will open. 
3.  According to the command which will appear in the window, press the keyfob button. 
4.  When the keyfob serial number is displayed in the window, click on the "OK" button. The "New" 

window will close. The serial number of the new keyfob will be shown in the "S/N" column. 

Assigning a zone to keyfob button (combination of buttons) 

1.  Click on the field corresponding to the button (combination of buttons) to which you want to assign 

a zone. 

2.  Enter the zone number and press ENTER. 

Removing a 433 MHz keyfob by means of the 

D

LOAD

X

 program 

1.  Click on the field in "S/N" column next to the name of user whose keyfob is to be removed. 
2.  Click on the "Delete" button. 
3.  In the window which will be displayed, click on the “Yes” button to confirm that you want to remove 

the keyfob. The keyfob serial number shown in the "S/N" column will be erased. 

5.  Work with the VERSA / VERSA Plus / VERSA IP control panel 

Using a keyfob, the user can run up to 6 functions. For the list of available function, refer to the control 
panel manuals. After adding a keyfob, default functions are assigned to its buttons (according to the 
given user schedule). You can change them to other ones. 
To manage the keyfobs, you can use a keypad (when adding or editing a user – refer to the control 
panel user manual) or the DLOADX program. 

Отзывы: