The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8
programmable wired outputs. It is supported by:
INTEGRA-series alarm control panels,
ACCO-NT access control panels.
The INT-ORS expander enables the system to be expanded by 8 programmable wired outputs.
It is supported by:
INTEGRA- / VERSA- / PERFECTA-series alarm control panels,
ACCO-NT access control panels.
The expanders are designed for mounting on 35 mm DIN rail, which facilitates installation process and
integration with other automation systems.
1. Features
8 programmable hardwired zones
only INT-IORS
:
– support for NO and NC type detectors, as well as roller shutter and shock detectors,
– support for Single EOL, Double EOL and Triple EOL configuration (Triple EOL when working
with INTEGRA Plus control panels),
– programming end-of-line resistor values.
8 programmable relay outputs for control of the electrical devices supplied with 230 VAC.
Capable of being integrated with a SATEL power supply unit (operation in "expander with power
supply" mode).
Connectable to RS-485 bus (firmware update through the bus).
35 mm DIN rail mountable.
2. Specifications
Supply voltage ................................................................................................................ 12 VDC
±
15%
Standby current consumption
INT-IORS ............................................................35 mA
INT-ORS .............................................................35 mA
Maximum current consumption
INT-IORS .......................................................... 350 mA
INT-ORS ........................................................... 310 mA
Relay output (resistive load) .......................................................................................... 16 A / 230 VAC
+12 output ...................................................................................................................... 2,5 A / 12 VDC
Environmental class according to EN50130-5 ...................................................................................... II
Operating temperature range ........................................................................................... -10
°C...+55°C
Maximum humidity ...................................................................................................................... 93
±
3%
Dimensions ................................................................................................................ 122 x 93 x 58 mm
Weight
INT-IORS ............................................................. 300 g
INT-ORS .............................................................. 285 g
3. Description
Description of terminals:
NO
- relay output normally open contact.
C
- relay output common contact.
NC
- relay output normally closed contact.
Z1...Z8
- zones.
only INT-IORS
COM
- common ground.
+12
- +12 VDC power input / output.
Do not connect power to the terminals, if the dedicated power supply unit is connected
to the connector on electronics board.