The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8 
programmable wired outputs. It is supported by: 

  INTEGRA-series alarm control panels, 

  ACCO-NT access control panels. 

The  INT-ORS  expander  enables  the  system  to  be  expanded  by  8  programmable  wired  outputs. 
It is supported by: 

  INTEGRA- / VERSA- / PERFECTA-series alarm control panels, 

  ACCO-NT access control panels. 

The expanders are designed for mounting on 35 mm DIN rail, which facilitates installation process and 
integration with other automation systems. 

1.  Features 

  8 programmable hardwired zones 

only INT-IORS

–  support for NO and NC type detectors, as well as roller shutter and shock detectors, 
–  support for Single EOL, Double EOL and Triple EOL configuration (Triple EOL when working 

with INTEGRA Plus control panels), 

–  programming end-of-line resistor values. 

  8 programmable relay outputs for control of the electrical devices supplied with 230 VAC. 

  Capable of being integrated with a SATEL power supply unit (operation in "expander with power 

supply" mode). 

  Connectable to RS-485 bus (firmware update through the bus). 

  35 mm DIN rail mountable. 

2.  Specifications 

Supply voltage ................................................................................................................ 12 VDC 

±

15% 

Standby current consumption 

INT-IORS ............................................................35 mA 
INT-ORS .............................................................35 mA 

Maximum current consumption 

INT-IORS .......................................................... 350 mA 
INT-ORS ........................................................... 310 mA 

Relay output (resistive load) .......................................................................................... 16 A / 230 VAC 
+12 output ...................................................................................................................... 2,5 A / 12 VDC 
Environmental class according to EN50130-5 ...................................................................................... II 
Operating temperature range ........................................................................................... -10

°C...+55°C 

Maximum humidity ...................................................................................................................... 93

±

3% 

Dimensions ................................................................................................................ 122 x 93 x 58 mm 
Weight 

INT-IORS ............................................................. 300 g 
INT-ORS .............................................................. 285 g 

3.  Description 

Description of terminals: 
NO

 

-  relay output normally open contact. 

C

 

-  relay output common contact. 

NC

 

-  relay output normally closed contact. 

Z1...Z8

  -  zones. 

only INT-IORS

 

COM

 

-  common ground. 

+12 

-  +12 VDC power input / output. 

Do not connect power to the terminals, if the dedicated power supply unit is connected 
to the connector on electronics board. 

Содержание INT-IORS

Страница 1: ...N rail mounted zone and output expander INT ORS DIN rail mounted output expander EN Firmware version 6 01 int iors_en 08 22 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 ww...

Страница 2: ...ions or repairs not authorized by the manufacturer shall void your rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technica...

Страница 3: ...tor values 8 programmable relay outputs for control of the electrical devices supplied with 230 VAC Capable of being integrated with a SATEL power supply unit operation in expander with power supply m...

Страница 4: ...tches used to configure the expander see Configuring the expander connector for a SATEL power supply unit e g APS 412 4 Configuring the expander Address setting An individual address must be set in th...

Страница 5: ...IORS zones depends on the selected type of device see table 2 INT IORS INT IORSPS INT PPPS CA 64 PP support for roller shutter and shock detectors support for Triple EOL configuration INTEGRA Plus pro...

Страница 6: ...nder expander w o power supply expander with power supply ON INT ORS INT ORSPS OFF INT O CA 64 O INT OPS CA 64 OPS Table 6 5 Installation and start up Disconnect power before making any electrical con...

Страница 7: ...the dedicated expander connector or connect the power leads to the 12 and COM terminals the expander may be powered directly from the control panel from an expander with power supply or from a power s...

Страница 8: ...expander 6 Updating the expander firmware 1 Use the RS 485 bus to connect the expander to the ACCO USB converter see the ACCO USB converter manual 2 Connect the ACCO USB converter to the computer USB...

Отзывы: