Satel GRAPHITE Скачать руководство пользователя страница 4

GRAPHITE 

SATEL 

The  GRAPHITE  detector  detects  motion  in  the  protected  area.  This  manual  applies  to  the 
detector with electronics version H. 

1.  Features 

  Motion detection with passive infrared sensor (PIR). 

  Adjustable detection sensitivity. 

  Digital motion detection algorithm. 

  Digital temperature compensation. 

  Pet immunity up to 15 kg. 

  Built-in end-of-line resistors (2EOL: 2 x 1.1 k

). 

  LED indicator. 

  Remote LED enable / disable. 

  Alarm memory. 

  Supervision of motion detection system and supply voltage. 

  Tamper protection against enclosure opening. 

  Adjustable mounting bracket included. 

2.  Description 

The alarm output will turn on for 2 seconds when the infrared sensor (PIR) detects motion. 

Supervision features 

In  the  event  of  the  voltage  drop  below  9  V  (±  5%)  for  more  than  2 seconds  or  the  motion 
detection  system  failure,  the  detector  will  signal  a  trouble.  The  trouble  is  indicated  by  the 
alarm output turning on and the LED lighting up. Signaling will continue as long as the trouble 
exists. 

LED indicator 

The LED indicates: 

  warm-up 

– flashing for about 30 seconds, 

  alarm memory 

– flashing rapidly, 

  alarm 

– ON for 2 seconds, 

  trouble 

– ON for entire duration of the trouble. 

Enabling the LED by using a jumper 

If you put a jumper across the LED pins as shown in Fig. 4, the LED will be enabled, i.e. it will 
indicate the events described above (the LED cannot be enabled / disabled remotely). If you 
put a jumper across the LED pins as shown in Fig. 5, the LED will be disabled, i.e. it will only 
indicate warm-up and trouble (but the LED can be enabled / disabled remotely). 

Remote LED enable / disable 

The  LED  terminal  is  provided  to  allow  remote  LED  enable / disable.  When  the  terminal  is 
connected to common ground, the LED is enabled. When the terminal is disconnected from 
common ground, the LED is disabled. 

If  the  detector  is  used  in  the  INTEGRA / INTEGRA  Plus  alarm  system,  you  can  connect  to 
the terminal the OC type control panel output programmed e.g. as “Zone test status” or “BI 
switch”. 

Содержание GRAPHITE

Страница 1: ...SATEL GRAPHITE 11 GRAPHITE Digital passive infrared detector EN Firmware version 2 00 graphite_en 06 21 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLSKA tel 48 58 320 94 00 www satel eu...

Страница 2: ...under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being...

Страница 3: ...NTS 1 Features 2 2 Description 2 Supervision features 2 LED indicator 2 Alarm memory 3 3 Electronics board 3 4 Selecting a mounting location 4 5 Installation 4 6 Start up and walk test 7 7 Specificati...

Страница 4: ...alarm output turning on and the LED lighting up Signaling will continue as long as the trouble exists LED indicator The LED indicates warm up flashing for about 30 seconds alarm memory flashing rapidl...

Страница 5: ...l not stop the alarm memory indication If the detector is used in the INTEGRA INTEGRA Plus alarm system you can connect to the MEM terminal the OC type control panel output programmed e g as Armed sta...

Страница 6: ...o not install the detector in places where it will be exposed to direct sunlight D or light reflected from other objects E Do not point the detector towards fans F air conditioners G or heat sources H...

Страница 7: ...SATEL GRAPHITE 5 6 Fasten the electronics board 7 Connect the wires to the corresponding terminals 8 Configure the detector settings 9 Replace the cover...

Страница 8: ...6 GRAPHITE SATEL...

Страница 9: ...ED will be flashing for 30 seconds to indicate warm up of the detector 2 When the LED stops flashing check if moving within the detector coverage area will make the LED to light up Figures 13 and 14 s...

Страница 10: ...y contact resistance 34 Detectable speed 0 3 3 m s Alarm signaling period 2 s Warm up period 30 s Recommended installation height 2 4 m Coverage area PET enabled 18 m x 16 m 54 PET disabled 20 m x 36...

Страница 11: ...SATEL GRAPHITE 9 Dimensions 63 x 96 x 49 mm Weight 94 g...

Отзывы: