Satel GPRS-A Скачать руководство пользователя страница 4

2 GPRS-A 

SATEL 

 

 

Fig. 1. GPRS-A module. 

 

  antenna connector (the antenna is delivered with the module). 

  SIM card slot. 

Inserting the SIM card into its slot before programming the card PIN code in the 
module is not recommended (if the card requires entering the PIN code).  

  APS connector for a SATEL power supply unit (e.g. APS-612). 

  LEDs indicating the module status. 

  RS-232 (TTL) port. 

  information on how to install the SIM card. 

Description of terminals 

+12V

 

–  power input (12 V DC ±15%). 

COM

 – 

common 

ground. 

RING, TIP

  –  terminals for connecting the control panel telephone communicator. 

S1…S3

 

–  1-Wire bus (1-Wire digital temperature sensors can be connected to the bus): 

S1

 – common ground, 

S2

 – data, 

S3

 – power supply. 

I1…I8

 

–  inputs. They can be programmed as digital (NC or NO type) or analog ones. 

O1...O2

 

–  OC type outputs (shorted to common ground when in active state). 

O3...O4

 

–  NO type relay outputs (normally open). 

AC

 

–  input for supervision of AC voltage presence. 

1.2.1  Antenna 

The GPRS-A module is delivered with an antenna. The antenna can be replaced with 
another antenna mounted on the enclosure or at some distance from it.  
Using the antenna mounted at some distance from the enclosure is recommended wherever 
thick masonry walls, metal partitions etc. may decrease the range of radio signal at the 
module installation place. 

Содержание GPRS-A

Страница 1: ...l monitoring module Quick installation guide Full manual is available on www satel eu Firmware version 1 02 gprs a_sii_en 08 18 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk Poland tel 48 58 320 94 0...

Страница 2: ...on the enclosure base FreeRTOS is used in this device www freertos org SATEL s goal is to continually upgrade the quality of its products which may result in some changes of their technical specifica...

Страница 3: ...the range of radio signal It is not advisable to install the module in close vicinity to electrical installations because this can result in malfunctioning of the device If the module is to comply wit...

Страница 4: ...hone communicator S1 S3 1 Wire bus 1 Wire digital temperature sensors can be connected to the bus S1 common ground S2 data S3 power supply I1 I8 inputs They can be programmed as digital NC or NO type...

Страница 5: ...e to be controlled by the module to the terminals of outputs Fig 2 Example of connecting supply and monitoring AC voltage presence 1 5 Connecting the digital temperature sensors 1 Wire You can connect...

Страница 6: ...the computer to the module Connect the computer to the module RS 232 TTL port To make the connection use the USB RS converter offered by SATEL Having connected the computer to the module you can conf...

Страница 7: ...uts 8 Number of outputs OC type 2 relay NO type 2 Supply voltage 12 V DC 15 Standby current consumption 80 mA Maximum current consumption 220 mA Maximum permissible voltage on AC input 25 V AC O1 O2 o...