Radio communication
The ASW-200 plug connects to the controller / control panel at regular time intervals to
provide information about its state (periodical communication). Additional communication
takes place when:
the plug button is pressed,
control commands are being sent to the plug.
In the ABAX 2 system, information about the supply voltage of the plug and the current
consumption of the appliance connected to the plug is also sent to the controller.
The information is shown in the ABAX 2 Soft program. It can also be read from the controller
using the Modbus RTU communication protocol.
Operating modes
You can select the operating mode when configuring the ASW-200 plug settings (see the
controller / control panel manual).
mode 0
– remote control only. Pressing the button does not control the appliance connected
to the plug but information is sent to the controller whenever the button is pressed.
mode 1
– remote or manual control. Press the button to turn ON / OFF the appliance
connected to the plug. Information about the appliance state is sent to the
controller / control panel.
mode 2
– remote or manual control but with option to manually block the remote control.
Press the button to turn ON / OFF the appliance connected to the plug. Press and
hold the button for about 3 seconds to block / unblock the remote control.
Information about the appliance state is sent to the controller / control panel.
Protection against overload and overheating
The plug has a firmware-based protection against overload or overheating.
Overload
If the current consumed by the appliance connected to the plug is greater than the rated
current of the plug (10 A), the plug will automatically turn off the appliance. In order to restore
the ability to control the appliance, disconnect the plug from the socket and plug it back in.
Do not use the plug to control appliances whose current consumption is greater than
10 A.
Overload is indicated by the LED indicator.
Overheating
If the temperature in the plug exceeds the maximum permissible value, the plug will
automatically turn off the appliance. When the plug cools down, the appliance will
automatically turn on and controlling the appliance will be possible.