background image

®

 

DIGITAL PASSIVE INFRARED DETECTOR  

AQUA RING 

CEILING MOUNT 

 

aquaring_e 06/04 

The microprocessor-based, fully 
digital AQUA series detectors 
feature high sensitivity and 
interference resistance. A dual pyro 
electric element is used in the AQUA 
RING detector. 

TERMINALS: 

NC 

- alarm relay (NC) 

TMP  - tamper contact (NC) 
COM  - ground (0V) 
12V 

- supply input (9-16V DC) 

 
Three pairs of pins are used to set the detector working parameters (see Table)  

 JP1 

JP2 

JP3 

Low sensitivity  

 

 

 

 

 

 

Medium sensitivity 

 

 

 

High sensitivity 

 

 

 

LED indicator ON 

 

 

 

LED indicator OFF 

 

 

 

 

- pins open 

- pins shorted 

The LED lights red when the detector is actuated, which enables the installer to 
check the detector for correct functioning and to approximately determine the 
protected area. 
For 30 seconds after the power is turned on, the detector remains in a starting 
state, which is signalized by rapid  LED blinking. Only then the detector enters its 
operational readiness state. 
The detector monitors the supply voltage. If the voltage drops below 9V (±5%) for 
more than 2 seconds, the detector will signalize a violation state until a voltage of 
minimum 9V (±5%) is restored. 

INSTALLATION 

The detector is designed for ceiling mount. Prior to installation, remove the 
electronics board and make adequate openings for screws and cable in the 
housing. 
Be careful so as not to soil or damage the pyro element in the process of 
installation. 

LED 

NC  NC  TMP TMP COM 12V 

  PIR SENS. 
LED ON/OFF 

JP1 

JP2 

JP3 

pyro element 

tamper contact 

relay 

positioning scale 

operating parameter 
setting pins 

Figure 1. View of detector electronics board 

 