Satel AOD-210 Скачать руководство пользователя страница 3

The AOD-210 outdoor detector can detect motion in a protected area. It is designed for 
operation within the ABAX 2 / ABAX two-way wireless system. This manual applies to the 
detector with firmware version 1.00 (or newer), which is supported by: 

 ABAX 

2: 

– ACU-220 

ACU-280 controller, 

–  ARU-200 repeater.  

 ABAX: 

–  ACU-120 / ACU-270 controller (firmware version 5.04 or newer), 
–  ARU-100 repeater (firmware version 2.02 or newer), 
–  INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware 

version of processor used to operate ABAX system 3.10 or newer). 

1  Features 

  Passive infrared (PIR) sensor and microwave sensor. 

 Adjustable 

detection 

sensitivity of both sensors. 

  Digital motion detection algorithm for both sensors. 

 Digital 

temperature compensation. 

  Pet immunity up to 20 kg. 

  Immunity to false alarms caused by moving but not changing their position objects (eg. 

branches of trees). 

 Creep 

zone. 

 Dusk 

sensor. 

  Encrypted two-way radio communication in the 868 MHz frequency band (AES standard 

for the ABAX 2 system). 

  Transmission channel diversity – 4 channels for automatic selection of the one that will 

enable transmission without interference with other signals in the 868 MHz frequency 
band (ABAX 2 system only). 

  Remote update of detector firmware (ABAX 2 system only). 

 Remote 

configuration. 

  Built-in temperature sensor (temperature measurement range from -40°C to +55°C). 

 Three 

LED 

indicators. 

  Supervision of motion detection system. 

  “ECO” option for longer battery life (ABAX 2 system only). 

  Battery status control. 

  Tamper protection against enclosure opening and removal from mounting surface. 

  Weatherproof enclosure featuring a very high mechanical strength. 

2  Description 

The detector occupies two positions on the device list: 

  the first one: motion detector, 

  the other one: dusk detector. 

Optionally the detector can occupy one position – only the motion detector is supported. 

Содержание AOD-210

Страница 1: ...AOD 210 Wireless outdoor dual technology motion detector Firmware version 1 00 aod 210_en 03 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...ontinually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our web...

Страница 3: ...g their position objects eg branches of trees Creep zone Dusk sensor Encrypted two way radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system Transmission channel diversi...

Страница 4: ...ned on remotely If the detector is used in the INTEGRA VERSA alarm system the operating mode may depend on the partition state partition disarmed passive mode partition armed active mode For more info...

Страница 5: ...rting the battery thus signaling the warm up of the detector The LEDs also work in the test mode in which they indicates periodical communication short flash of the red LED 80 milliseconds motion dete...

Страница 6: ...tamper switch activated by cover removal fixing screw holes On the other side of the electronic board is a tamper switch activated by removing the detector from the wall When mounting the detector on...

Страница 7: ...t should be mounted at a height of 2 4 m without any vertical deflection It must be borne in mind especially in the case of ball type bracket mounting 1 Remove the front cover Fig 4 2 Install the batt...

Страница 8: ...io signal strength at the place of future installation without having to put the detector there 7 Remove the front cover Fig 4 8 Remove the electronics module Fig 5 9 If the detector is to be mounted...

Страница 9: ...6 Check whether moving around within the detector coverage area will get the LEDs to come on Fig 9 shows the maximum detection range and the creep zone 17 End the test mode 4 1 Angle bracket mounting...

Страница 10: ...IV 2 Run the cable through the opening in the handle of the bracket 3 Using wall plugs and screws fasten the ball bracket to the wall Fig 8 V 4 Run the tamper switch wires through the hole made in the...

Страница 11: ...SATEL AOD 210 9...

Страница 12: ...ement range 40 C 55 C Temperature measurement accuracy 1 C Standby current consumption 75 A Maximum current consumption 30 mA Microwave frequency 24 125 GHz Detectable speed 0 3 3 m s Warm up period 4...

Страница 13: ...SATEL AOD 210 11 Maximum humidity 93 3 IP code IP54 Dimensions 65 x 138 x 58 mm Weight 182 g...