The less often communication between the controller and the wireless devices takes 
place, the lower energy consumption and the longer battery life are. 

In the case of the AMD-103 detector and ASP-100 siren, no communication takes 
place during polling.  

Higher sensitivity for jamming detection 

– if this option is enabled, the sensitivity of 

detection of radio communication jamming is boosted. 

Synchronize 

– this function starts the procedure of synchronization, i.e. checking for 

presence of other ABAX wireless system controllers working within the controller operating 
range. The controller will synchronize the response period so that the radio transmissions 
of some controllers should not be mutually jammed. Synchronization is performed 
automatically upon starting the controller and after each operation of adding/removing 
devices supported by it. 

Test mode 

– in the ABAX system the test mode can be started, in which: 

– LED indicators are enabled in the wireless devices (the LEDs are disabled during 

normal operation) – information provided by means of the LEDs depends on the device; 

–  signaling is blocked in the ASP-105 and ASP-205 sirens. 
The test mode is started/ended during polling, which results in a delay, its duration 
depending on the programmed response period. The test mode will be turned off 
automatically after 30 minutes of: 
–  starting the test mode from the DLOADX program (the 30-minute period is running from 

the moment of exiting the controller settings), 

–  exiting the service mode in the control panel. 

According to requirements of the EN50131 standard, the level of radio signals sent by 
wireless devices is reduced during the test mode operation. 

For the AMD-103 detector, entering the test mode remotely is not possible. 

6.  Wireless devices 

The wireless keypads constitute a special category of devices and therefore they are 
discussed in a separate section. 

6.1  Wireless devices supported by the controller 

Detectors 

  AFD-100 – wireless water flood detector. 

  AGD-100 – wireless glass-break detector. 

  AMD-100 – wireless magnetic contact. 

  AMD-101 – dual channel wireless magnetic contact. 

  AMD-102 – wireless magnetic contact with input for roller shutter detector. 

  AMD-103 – wireless magnetic contact. 

  AOD-200 – wireless outdoor dual technology motion detector. 

  APD-100 – wireless passive infrared detector. 

  APMD-150 – wireless dual technology motion detector. 

  ARD-100 – wireless reorientation detector. 

  ASD-110 – wireless smoke and heat detector. 

Содержание ACU-270

Страница 1: ...ABAX WIRELESS SYSTEM CONTROLLER ACU 270 Firmware version 5 02 acu 270_en 03 16 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...er the warranty SATEL s goal is to continually upgrade the quality of its products which may result in some changes of their technical specifications and firmware The current information on the introd...

Страница 3: ...ASP 100 wireless outdoor siren Irrespective of in conjunction with which control panel the controller is used you can select for some wireless devices whether the wireless device will take up one or t...

Страница 4: ...Programming the wireless devices 13 6 3 1 Parameters and options 13 6 3 2 Programming in the INTEGRA INTEGRA Plus system 15 6 3 3 Programming in the VERSA VERSA Plus VERSA IP system 17 6 4 Specific ch...

Страница 5: ...unnecessary Additionally the controller allows to operate the alarm system using the ABAX system two way keyfobs The name plate of the controller is located on the enclosure base After installation of...

Страница 6: ...al switches in ON position are shown in Table 1 The sum of numerical values assigned to switches 1 5 means the address set on the device The address must be different from that on the other devices co...

Страница 7: ...ncy the lower the number of devices that can work within each other s range 1 Open the enclosure of the controller Fig 2 2 Set the DIP switches as required see DIP switches 3 Place the enclosure base...

Страница 8: ...he module will be identified as ACU 100 5 Programming the controller Programming of the controller is carried out by means of the control panel using the LCD keypad in service mode INTEGRA INTEGRA Plu...

Страница 9: ...mber of tamper alarms from the module to three is disabled the feature prevents multiple logging of the same events and applies to successive uncleared alarms Response period communication with wirele...

Страница 10: ...the ASP 105 and ASP 205 sirens The test mode is started ended during polling which results in a delay its duration depending on the programmed response period The test mode will be turned off automati...

Страница 11: ...quality You can install the device permanently only after reaching the optimum level of radio signal The wireless devices must be registered to the alarm system This can be done using the LCD keypad o...

Страница 12: ...tor 20 unused unavailable 5 AMD 101 detector 21 AMD 101 detector 21 unused unavailable 6 22 AMD 101 detector 22 unused unavailable 7 23 unused unavailable 23 unused unavailable 8 ASP 105 siren 8 24 AS...

Страница 13: ...t for the controller If when new wireless devices have been added to the controller it turns out that next addresses are needed and these are taken up by other devices successful completion of the exp...

Страница 14: ...the device 7 digit serial number and press the key The serial number can be found on the electronics board or on the enclosure Each ARF 100 radio signal level tester has serial number 0000500 3 When...

Страница 15: ...t will appear on the display asking you whether the device is to be removed the device type and serial number will be shown Press the key 1 The device will be deleted 4 A message on the display will i...

Страница 16: ...magnetic contact The active reed switch is to be selected AMD 102 wireless magnetic contact with input for roller shutter detector The following is to be programmed active reed switch first zone numbe...

Страница 17: ...ons occupied by the siren thus allows to program two different signaling types maximum duration of signaling type of acoustic signaling optical signaling option ASW 100 E ASW 100 F 230 V AC wireless c...

Страница 18: ...100 enter 2 digits 1st digit sensitivity 1 low 2 medium or 3 high 2nd digit pet immunity option 0 disabled or 1 enabled ARD 100 enter a number from the 1 to 16 range to determine sensitivity 1 minimu...

Страница 19: ...ans of the DLOADX program 6 3 3 Programming in the VERSA VERSA Plus VERSA IP system DLOADX program You can configure wireless devices in the Versa Structure window Hardware tab after clicking on the c...

Страница 20: ...horter than in those which are periodically switched to the passive mode However if the specific character of a detector or its installation place is such that the number of violations is low switchin...

Страница 21: ...n ASP 105 installing the battery ASP 205 It enables installation work to be carried out Opening the tamper switch will not trigger loud signaling but information on tamper will be sent when in service...

Страница 22: ...rcuit if reverse polarity of the output has been programmed the circuit will be deenergized Depending on the operating mode information on the button status mode 0 or on the electric circuit status mo...

Страница 23: ...keyfob data In the case of the DLOADX program to write to a new controller the data on APT 100 keyfobs already assigned to the users open the Keyfobs ABAX window and INTEGRA 128 WRL click on the Write...

Страница 24: ...d to the user the new keyfob will have the same settings as the deleted one You can remove all keyfobs including their settings by means of the REM ABAX KEYFOB function available in the service mode i...

Страница 25: ...umber shown in the S N column will be erased 8 2 Keyfobs in the VERSA VERSA Plus VERSA IP system The functions which can be started using the keyfobs and the information that can be presented on the L...

Страница 26: ...presented on the LEDs 1 Click on the field corresponding to the selected LED 2 Right click on your mouse A drop down menu will appear in which you are to select the new information 9 Specifications Su...

Страница 27: ...added Information on ASP 100 siren has been added p 8 9 13 and 15 Information on AOD 200 detector has been added p 8 14 and 16 Note about wireless devices which can take up one or two positions on th...

Отзывы: