Satel ACCO-KP2 Скачать руководство пользователя страница 20

SATEL 

ACCO-KP2 

18 

  the user tries again to enter or exit 

– the “Anti Passback” option is enabled, 

  the module operates in the mantrap / airlock configuration and the other door is open, 

 

the reader is blocked by the “Anti-Scanner” function. 

7.3  Other functions 

The following functions are available when the door status is controlled. 

7.3.1  Blocking the door 

1.  If  the  LED  is  ON  in  green  (the  door  operates  in  the  normal  mode),  make  sure  that  the 

door is closed. 

2.  Tap the iButton on the reader and hold it for about 3 seconds. The door will be blocked. 

The LED will start flashing slowly in red. 

7.3.2  Unblocking the door 

1.  If the LED is ON in green (the door operates in the normal mode), get access and open 

the door (see p. 17). 

2.  Tap the iButton on the reader and hold it for about 3 seconds. The door will be unblocked. 

The LED will start flashing slowly in green. 

7.3.3  Restoring the door to normal operation mode 

If  the  LED  is  flashing  slowly  in  red  (door  blocked)  or  in  green  (door  unblocked),  tap  the 
iButton on the reader and hold for about 3 seconds. The door will switch to normal operation 
mode. The LED will turn ON in green. 

8.  Unlock button 

The  installer  can  connect  to  the  module  a  button  or  a  different  device  (e.g.  a  detector) 
intended to unlock the door. In such case,  the door is unlocked without the  need to identify 
the  user  by  the  module.  This  solution  can  be  used  e.g.  for  leaving  the  premises  (when  the 
entry  to  the  premises  is  controlled  but  the  exit  is  not)  or  when  access  is  granted  by  the 
doorman. 

9.  Other ways to block the door 

The door can also be blocked in one of the following ways: 

 

after the module input programmed as “Door blocking” is activated (e.g. by using a switch), 

 

after  the  module  input  programmed  as  “Alarm  –  block  door”  is  activated  (e.g.  by  using 
a control panel output), 

If  the  door  has  been  blocked  by  means  of 

the  “Alarm  –  block  door”  type  of  input, 

the door status can only be changed by the user by means of the terminal. 

  automatically, at a specific time (it can be programmed in the module since when and until 

when the door is to be blocked), 

  automatically,  according  to  the  access  schedule  (the  schedule  defines  at  what  times  the 

door is to be blocked). 

Содержание ACCO-KP2

Страница 1: ...21 ACCO KP2 SATEL ACCO KP2 Access control module ACCO USER MANUAL EN Firmware version 1 00 acco kp2_u_en 06 22 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...s under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software The current information on the introduced...

Страница 3: ...l operation mode 9 4 3 5 Changing the code 10 4 3 6 Module data 10 4 4 Other functions available when the proximity card is used 10 4 4 1 Blocking the door 10 4 4 2 Unblocking the door 10 4 4 3 Restor...

Страница 4: ...the door 16 6 5 2 Unblocking the door 16 6 5 3 Restoring the door to normal operation mode 17 7 Using the CZ DALLAS reader 17 7 1 Description of the CZ DALLAS reader 17 7 1 1 Bicolor LED 17 7 2 Unlock...

Страница 5: ...pecified in the access schedule Access time time during which you will be able to open the door after you get access Alarm warning of a situation that may compromise the operation of the access contro...

Страница 6: ...ntrolled It is the default operating mode of the door Proximity card passive transponder in the form of a card key tag etc Each card has a unique and fixed code used to identify the user Quit entry ex...

Страница 7: ...1 The user with ID number 00001 cannot be deleted from the module The user s Administrator and Change code rights cannot be revoked either You should change the factory code before you start using the...

Страница 8: ...lashing slowly door blocked permanently locked after the Alarm block door type of input is activated green ON door unblocked permanently unlocked flashing slowly door unblocked permanently unlocked af...

Страница 9: ...4 1 5 Audible signaling 1 short beep access granted and door unlocked 2 short beeps door blocked unblocked or restored to normal mode 3 short beeps waiting for the second identifier to be used 1 long...

Страница 10: ...flashing open the door Getting access by using the proximity card 1 Present the card on the keypad reader 2 When the LED will start flashing open the door Getting access by using two identifiers 1 Use...

Страница 11: ...door use to unblock the door This function is available to the user with the Switching right Block door use to block the door This function is available to the user with the Switching right Normal mo...

Страница 12: ...mode make sure that the door is closed 2 Present the card on the keypad reader and hold for about 3 seconds The door will be blocked The LED will turn ON in the keypad 4 4 2 Unblocking the door 1 If n...

Страница 13: ...lock door type of input is activated flashing rapidly access to door granted red ON alarm flashing alarm memory 5 1 2 Keys Use the number keys to enter the code for user authorization Use the other ke...

Страница 14: ...door status block unblock restore to normal mode because the door status is not controlled 1 very long beep access denied the keypad is blocked by the Anti Scanner function Long beep lasting 10 secon...

Страница 15: ...will be blocked The LED will turn ON in the keypad 5 3 2 Unblocking the door 1 If no LED is turned ON the door operates in the normal mode get access and open the door see p 12 2 Enter the code and p...

Страница 16: ...r is connected to the module the users can use the proximity card The reader supports the Unique 125 kHz proximity cards and key fobs 6 1 Description of the CZ EMM and CZ EMM2 readers Fig 4 CZ EMM and...

Страница 17: ...odically dimmed down reader blocked by the Anti Scanner function 6 2 2 Bell key The CZ EMM4 reader has the key Ask the installer what function is started by the key 6 3 Audible signaling 1 short beep...

Страница 18: ...or 6 4 2 Access denied The door will remain locked if the identifier is unknown the user cannot get access because the user is not authorized to unlock the door according to the access schedule the do...

Страница 19: ...ed red ON reader blocked because keypad has been connected flashing slowly door blocked permanently locked ON but periodically dimmed down reader blocked by the Anti Scanner function 7 2 Unlocking the...

Страница 20: ...ap the iButton on the reader and hold for about 3 seconds The door will switch to normal operation mode The LED will turn ON in green 8 Unlock button The installer can connect to the module a button o...

Страница 21: ...cally at a specific time it can be programmed in the module since when and until when the door is to be unblocked automatically according to the access schedule the schedule defines at what time the d...

Отзывы: