background image

SATEL 

ACD-220 

1.  Remove the detector cover (Fig. 3). The enclosure opening tool, shown in the illustration, 

is included in the detector delivery set. 

 

2.  Insert the battery and add the detector to the wireless system (see the ABAX 2 controller 

manual).  The  sticker  with  serial  number  which  shall  be  entered  when  registering  the 
detector in the system can be found on the electronics board. 

In the VERSA alarm system, you can add and configure the ACD-220 detector only by 
using the DLOADX program. 

3.  Replace the detector cover. 

4.  Place the detector at its future mounting location. 

5.  Check the level of signal received from the detector by the ABAX 2 controller. If the signal 

level  is  lower  than  40%,  select  another  mounting  location.  Sometimes,  it  is  sufficient  to 
shift the device ten or twenty centimeters. 

You can use the ARF-200 tester to test the radio signal strength at the future mounting 
location without having the detector physically there. 

6.  Remove the detector cover (Fig. 3). 

7.  Use wall plugs (anchors) and screws to mount the enclosure base to the surface (Fig. 4). 

The  wall  plugs  delivered  with  the  device  are  intended  for  concrete,  brick,  etc.  For  other 
types of surface (drywall, styrofoam), use the appropriately selected wall plugs. 

8.  Replace the detector cover. 

9.  Configure the detector settings (sensitivity of  IR sensor etc. 

– see the ABAX 2 controller 

manual). 

10. Enable the test mode (see the ABAX 2 controller manual). 

11. Check  whether  moving  around  within  the  detector  coverage  area  will  make  the  LED 

light up. Fig. 5 shows the maximum coverage area. 

12. Exit the test mode. 

Содержание ABAX 2

Страница 1: ...ACD 220 Wireless curtain detector EN Firmware version 1 00 acd 220_en 10 21 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Страница 2: ...device was placed on the market after 13 August 2005 The device meets the technical regulations of the Eurasian Customs Union SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at https support satel eu Hereby SATEL...

Страница 3: ... communication 2 Alarms 2 Operating modes 2 Energy saving mode ECO 3 Test mode 3 LED 3 Supervision of motion detection system 3 Battery status control 3 3 Electronics board 3 4 Selecting a mounting location 4 5 Installation 4 6 Specifications 6 ...

Страница 4: ...her signals in the 868 MHz 915 MHz frequency band Remote update of detector firmware Remote configuration Built in temperature sensor temperature measurement range from 10 C to 55 C LED indicator Supervision of motion detection system ECO option for longer battery life Battery status control Tamper protection against enclosure opening and removal from mounting surface 2 Description Radio communica...

Страница 5: ...e battery is inserted to indicate warm up of the detector The LED also works in the test mode in which it indicates periodical communication short flash 80 milliseconds alarm ON for 2 seconds Supervision of motion detection system When the motion detection system starts malfunctioning the detector will report an alarm during periodical communication The alarm will keep going until the fault is cle...

Страница 6: ...ded by the manufacturer or handling the battery improperly Do not crush the battery cut it or expose it to high temperatures throw it into the fire put it in the oven etc Do not expose the battery to very low pressure due to the risk of battery explosion or leakage of flammable liquid or gas Be particularly careful during installation and replacement of the battery The manufacturer is not liable f...

Страница 7: ...r than 40 select another mounting location Sometimes it is sufficient to shift the device ten or twenty centimeters You can use the ARF 200 tester to test the radio signal strength at the future mounting location without having the detector physically there 6 Remove the detector cover Fig 3 7 Use wall plugs anchors and screws to mount the enclosure base to the surface Fig 4 The wall plugs delivere...

Страница 8: ... to 2 years Temperature measurement range 10 C 55 C Temperature measurement accuracy 1 C Standby current consumption 70 µA Maximum current consumption 15 mA Detectable speed 0 3 1 m s Warm up period 5 s Coverage area 5 m x 1 m 15 Complied with standards EN 50130 4 EN 50130 5 Environmental class according to EN 50130 5 II Operating temperature range 10 C 55 C Maximum humidity 93 3 Dimensions 20 x 1...

Отзывы: