SATEL
ACD-220
5
1. Remove the detector cover (Fig. 3). The enclosure opening tool, shown in the illustration,
is included in the detector delivery set.
2. Insert the battery and add the detector to the wireless system (see the ABAX 2 controller
manual). The sticker with serial number which shall be entered when registering the
detector in the system can be found on the electronics board.
In the VERSA alarm system, you can add and configure the ACD-220 detector only by
using the DLOADX program.
3. Replace the detector cover.
4. Place the detector at its future mounting location.
5. Check the level of signal received from the detector by the ABAX 2 controller. If the signal
level is lower than 40%, select another mounting location. Sometimes, it is sufficient to
shift the device ten or twenty centimeters.
You can use the ARF-200 tester to test the radio signal strength at the future mounting
location without having the detector physically there.
6. Remove the detector cover (Fig. 3).
7. Use wall plugs (anchors) and screws to mount the enclosure base to the surface (Fig. 4).
The wall plugs delivered with the device are intended for concrete, brick, etc. For other
types of surface (drywall, styrofoam), use the appropriately selected wall plugs.
8. Replace the detector cover.
9. Configure the detector settings (sensitivity of IR sensor etc.
– see the ABAX 2 controller
manual).
10. Enable the test mode (see the ABAX 2 controller manual).
11. Check whether moving around within the detector coverage area will make the LED
light up. Fig. 5 shows the maximum coverage area.
12. Exit the test mode.