26
Point
ID
Description
Options/Range/Format
2
Units
2
Type
R
/
W
Notes
0xB209
Timestamp
sec
UINT32
R
0xB20A
0xB20B
Max. I3 Current
Timestamp
0-Imax
U2
sec
UINT32
UINT32
R
R
Maximum Total Values
0xB280
0xB281
Max. Total kW
Timestamp
-Pmax-Pmax
U3
sec
INT32
UINT32
R
R
0xB282
0xB283
Max. Total kvar
Timestamp
-Pmax-Pmax
U3
sec
INT32
UINT32
R
R
0xB284
0xB285
Max. Total kVA
Timestamp
0-Pmax
U3
sec
UINT32
UINT32
R
R
0xB286
0xB287
Max. Total PF
Timestamp
-1000-1000
0.001
sec
INT32
UINT32
R
R
Maximum Auxiliary Values
0xB300
0xB301
Not used
0
UINT32
UINT32
R
R
0xB302
0xB303
Max. In Current
Timestamp
0-Imax
U2
sec
UINT32
UINT32
R
R
0xB304
0xB305
Max. Frequency
Timestamp
0-Fmax
0.01Hz
sec
UINT32
UINT32
R
R
Billing Summary Maximum Demands
0xB340
0xB341
Summary register #1 Maximum Demand
Timestamp
0-Pmax
U3
UINT32
R
0xB342
0xB343
Summary register #2 Maximum Demand
Timestamp
0-Pmax
U3
UINT32
R
0xB344
0xB345
Summary register #3 Maximum Demand
Timestamp
0-Pmax
U3
UINT32
R
0xB346
0xB347
Summary register #4 Maximum Demand
Timestamp
0-Pmax
U3
UINT32
R
Maximum Demands
0xB380
0xB381
V1/V12 Maximum volt demand
Timestamp
0-Vmax
U1
sec
UINT32
UINT32
R
R
1
0xB382
0xB383
V2/V23 Maximum volt demand
Timestamp
0-Vmax
U1
sec
UINT32
UINT32
R
R
1
0xB384
0xB385
V3/V31 Maximum volt demand
Timestamp
0-Vmax
U1
sec
UINT32
UINT32
R
R
1
0xB386
0xB387
I1 Maximum ampere demand
Timestamp
0-Imax
U2
sec
UINT32
UINT32
R
R
0xB388
0xB389
I2 Maximum ampere demand
Timestamp
0-Imax
U2
sec
UINT32
UINT32
R
R
0xB38A
0xB38B
I3 Maximum ampere demand
Timestamp
0-Imax
U2
sec
UINT32
UINT32
R
R
0xB38C
Not used
0
UINT32
R
Содержание EM133