INSTALLATION & SET-UP

  10

3 . 1. 2 Timing

TIMING

 determines the source for the LINE E1 transmit clock, and is set by  bit-switch no1. 

The options are

 ON 

or 

OFF.

With the switch set to 

ON

, the E1 transmit clock is derived from the WC1000's own 

internal oscillator.

With the switch set to 

OFF

, the E1 transmit clock is derived from the LINE E1 receive

 

clock.

3 . 1. 3 E1 Port select RJ45/BNC 

This single switch is used to select which type of connector (RJ45 or BNC) is to be used to 
connect the E1 line.

With the switch set to 

ON

, the BNC ports are selected to give G.703 75 ohm unbalanced 

interface.

With the switch set to 

OFF

, the RJ45 port is selected to give G.703 120 ohm balanced 

interface.

3 . 1. 4  Loopback test

This switch is used to initiate loop testing. It is fully described in the next section.

The switch is set to 

ON

 for normal operation of the unit without any loopbacks.

With the switch set to 

OFF

, Loopback is applied, so that Transmit data = Received data on 

the E1 port.  

3 . 1. 5 LAN mode

Bit-switch 

ON:

 100 Mbps Full Duplex operation. 

Note that this option enables 100M full duplex connection to be implemented. Auto-negotiate 
does not  distinguish between full versus half duplex modes when negotiating with a fixed 
(i.e. non-negotiating) 100Mbps port.

Bit-switch 

OFF: 

Auto-negotiate Mode (default).

3 . 1. 6 Auto MDI/MID-X

With switch set to 

ON

, the LAN ports are fixed as MDI-X for direct connection to a PC. This 

may be necessary for reliability when connecting some older non-auto hubs 

With switch set to 

OFF

, the LAN ports automatically sense the interface and switch between 

MDI and MDI-X connections.

3 . 1. 7  E1 Line port

No configuration of the E1 Line port is required. Operation is unframed. The Line Coding 
setting is built into the unit (no bit-switch) and cannot be altered. It is HDB3 (High-Density 
Binary 3). The maximum line rate is 2.048Mbps. The maximum corresponding packet rate 
is 4064 packets per second.

3 . 1. 8 MAC FCS

On older units, bit-switch 7 enabled the transmission of the MAC FCS. This feature has now 
been disabled and the WC1000 always strips the MAC FCS from the ethernet packet.

Содержание WC1000

Страница 1: ...Metrodata WAN in a CAN WC1000 LAN Extender Installation Guide WC1000 ...

Страница 2: ...e user s network design and workload characteristics The WC1000 Ethernet Switch can switch between local LANs connected to its four ports and the unit may thus reduce the need for local LAN hubs and switches The Ethernet switch has full wirespeed filtering so that the WAN port carries only traffic destined for the remote WAN linked site and an efficient HDLC encapsulation of packets ensures maximu...

Страница 3: ...e screened connector shell and not connected to any pins of the connector Failure to use the correct connector may compromise EMC compliance 1 5 EN55022 Declaration The WC1000 is a Class A product In a domestic environment it may cause radio interference in which case the user may be required to take adequate measures 1 6 FCC Declaration This equipment has been tested and found to comply with the ...

Страница 4: ...he unit as shown in the figure below Figure 2 2 Rear panel status LED 2 3 Status display LAN ports Each LAN port RJ45 connector on the rear panel has two miniature LEDs mounted on it The left hand green LED shows link activity and the right hand yellow LED shows operation at 100Mbps when it is illuminated Status LED Meaning Off No mains power present On Green Status OK On Red E1 WAN port LOS Alarm...

Страница 5: ...nection to be made Figure 2 3 48VDC connections Note The WC1000 must be connected to mains safety earth for correct operation Excessive voltages are present inside the unit There are no user serviceable parts inside the unit and the cover should not be removed by unqualified personnel The unit must not be exposed to damp or condensing conditions 2 5 Unbalanced BNC E1 Line port The network is conne...

Страница 6: ...PABX is straight through Connections are defined in the table below Figure 2 7 Connection from WC1000 to terminal device Pin Function 1 Tx tip 2 Tx ring 3 Tx shield 4 Rx tip 5 Rx ring 6 Rx shield 7 Not connected 8 Not connected DSU port pin DSU port function Terminal port pin Terminal port function 1 Tx tip 1 Rx tip 2 Tx ring 2 Rx ring 3 Tx shield 3 Rx shield 4 Rx tip 4 Tx tip 5 Rx ring 5 Tx ring ...

Страница 7: ...r layout Figure 2 4 shows both the plug and socket head on so that any connecting wires are behind the connector The connector numbering is shown Figure 2 9 RJ45 layout DSU port pin DSU port function Network port pin Network port function 1 Tx tip 4 Rx tip 2 Tx ring 5 Rx ring 3 Tx shield 6 Rx shield 4 Rx tip 1 Tx tip 5 Rx ring 2 Tx ring 6 Rx shield 3 Tx shield 7 Not connected Not connected Not con...

Страница 8: ... The total maximum attenuation of the cable attached to the network port must not exceed 6dB when measured at 1 024 MHz The frequency attenuation characteristic of the cables attached to the network port shall follow a root frequency law This port type is approved to CTR12 CTR13 Cable Max Length metres Belden 8132 28 AWG 175 Belden 9841 24 AWG 300 ...

Страница 9: ...plex mode There is a miniature LED on the lower right corner of each RJ45 socket on the rear panel which is illuminated yellow when operation is at 100 Mbps The miniature LED on the lower left corner of each RJ45 socket is illuminated green when the link is active The RJ45 connector layout for an auto sensing MDI MDI X port is shown below Figure 2 11 LAN port connector layout The pin numbering for...

Страница 10: ... Loop 2 E1 Port select BNC RJ45 3 Loopback test None Remote 4 Normal 5 Normal 6 Normal 7 LAN Mode 100M FD Auto negotiate 8 Auto MDI MDI X Disabled Enabled Serial No WC1000 LAN TO E1 CONVERTER AC For product manual and other information www metrodata co uk Metrodata Ltd TW20 8RY UK Tel 44 0 1784 744700 Fax 44 0 1784 744730 17 08 299A Part Number 80 05 541 OFF ON 1 2 3 4 5 6 7 8 Bitswitch Control ON...

Страница 11: ...eived data on the E1 port 3 1 5 LAN mode Bit switch ON 100 Mbps Full Duplex operation Note that this option enables 100M full duplex connection to be implemented Auto negotiate does not distinguish between full versus half duplex modes when negotiating with a fixed i e non negotiating 100Mbps port Bit switch OFF Auto negotiate Mode default 3 1 6 Auto MDI MID X With switch set to ON the LAN ports a...

Страница 12: ... status LED to ensure that it is continuously lit green Warning Do not connect the WC1000 to excessive voltage Read the safety information before continuing 3 3 Optional rackmounting Rackmounting kits may be used to mount two WC1000 units side by side in a 19 rack The first two of these kits have a flat mounting plate with separate cut outs for power cables and signal cables 80 05 252 is suitable ...

Страница 13: ... Activity 1 2 3 4 SUBSCRIBER PORT 10 100 BASE T Green Link Act Yellow Speed Tx Rx Line Activity 1 2 3 4 Pin1 48V Pin3 0V L _ _ SUBSCRIBER PORT 10 100 BASE T Green Link Act Yellow Speed Tx Rx Line Activity 1 2 3 4 Pin1 48V Pin3 0V L _ _ Recessed space to accommodate fibre bends WC1000 WC1000 Part No 80 05 256 SUBSCRIBER PORT 10 100 BASE T Green Link Act Yellow Speed Tx Rx Line Activity 1 2 3 4 SUBS...

Страница 14: ...vity by observing the green Tx and Rx LED s on the rear panel If packets are being transmitted or received the LEDs will be ON If they are dark there is no traffic being forwarded over the WAN link or there is a problem with the WAN link This could be bit errors on the data lines or no clocks present WC1000 with BNC connectors Step 3A If the status LED is red first check that the PORT SELECT bit s...

Страница 15: ...e correct speed but in half duplex mode and with a heavy error count 4 3 Test Loop Figure 4 2 Test loop on remote WC1000 Set the remote WC1000 base panel bit switch labelled LOOPBACK to the ON position When the TEST LOOP is activated at the remote WC1000 the signal received from the local Bit Error Rate Tester BERT unit at the E1 port is passed directly back to the BERT at the line interface If th...

Страница 16: ...3 compliant barrier provided on the E1 interface Framing Unframed Encapsulation HDLC Clocking options E1 Line Internal or Loop E1 line receive clock Line Rate 2 048 Mbps Maximum packet rate 4064 pps packet per sec LED Indicators Tx Rx Packet Alarm Alarms E1 LOS Diagnostics External Loop Test initiated by bit switch Subscriber LAN Ports Definition LAN Interface 4 x RJ45 Auto switched MDI or MDI X o...

Отзывы: