Document Part No: 76-02-050A

Metrodata BC1X00 

Baseband Converter Range 

Installation Guide

 BC1X00

Содержание BC1X00

Страница 1: ...Document Part No 76 02 050A Metrodata BC1X00 Baseband Converter Range Installation Guide BC1X00 ...

Страница 2: ...w Figure 1 1 BCX00 application The BC1X00 range of converters has been designed to be plug and go conforming to appropriate standards physically very compact and rack mountable in sets of 2 using a dual face plate or 18 units in a rack mount kit for large installations Metrodata are continually developing new models so if the interface combination required is not listed in this guide please contac...

Страница 3: ...ence in which case the user will be required to correct the interference at its own expense 1 6 RoHS Compliance The BC1X00 is compliant with the EU RoHS directive 2002 95 EC The RoHs directive bans the use of six hazardous materials in products placed on the market after July 1st 2006 The six banned materials are Lead Mercury Hexavalent Chromium Polybrominated Biphenyls Polybrominated Diphenyl Eth...

Страница 4: ... connected to a supply socket that is physically located close to the unit and is easily accessible Safety Notes Excessive voltages are present inside the unit There are no user serviceable parts inside the unit and the cover should not be removed by unqualified personnel The unit must not be exposed to damp or condensing conditions Product Watts Power Consumption Current Range mA for 100 250 VAC ...

Страница 5: ...gle Metrodata BC1X00 model and for UK shipments only a power cable If there is any visible damage do not attempt to connect the device Contact your Supplier or Metrodata Technical Support for advice and assistance The rear panels of typical BC1X00 units are shown above in this section Note that the current rating shown on the rear panel label is the maximum current which corresponds to the lowest ...

Страница 6: ...RD A From DCE 4 Request to Send A To DCE 5 Clear to Send A From DCE 6 Data Set Ready A From DCE 7 Signal Ground Ground 8 Data Carrier Detect A RR A From DCE 9 Receive Timing B RT B From DCE 10 Data Carrier Detect B RR B From DCE 11 Terminal Timing B TT B To DCE 12 Send Timing B ST B From DCE 13 Clear to Send B From DCE 14 Send Data B SD B To DCE 15 Send Timing A ST A From DCE 16 Receive Data B RD ...

Страница 7: ...al state OFF Pin Pin Signal Signal name Direction 1 26 SG Signal Ground 2 27 RT Receive Timing A To DTE 3 28 CA DCE Available A To DTE 4 29 RD Receive Data A To DTE 5 30 LC Loopback C To DTE 6 31 ST Send Timing A To DTE 7 32 SG Signal Ground 8 33 TA DTE Available A To DCE 9 34 TT Terminal Timing A To DCE 10 35 LA Loopback A To DCE 11 36 SD Send Data A To DCE 12 37 LB Loopback B To DCE 13 38 SG Sig...

Страница 8: ... EN60950 Clause 2 3 2 6 Connect the HSSI port The HSSI port of the BC1X00 is presented on an industry standard miniature 50 way connector The same connector is used for both the BC1000 DTE and BC1100 DCE ports HSSI is a fault tolerant interface and should not be damaged by connecting similar port types e g DTE to DTE or DCE to DCE In such circumstances however normal operation will not be possible...

Страница 9: ...te complete with one or two BC1X00 units into the 19 rack using the locating holes at the ends of the adaptor plate Ensure that the bit switches are set correctly before installing the rack mount kit 2 9 Power up the BC1X00 The unit requires 100 250 VAC 50 60 Hz AC supply An alternative 48VDC power supply is available as a custom order item for all models See Section 2 for further details of power...

Страница 10: ...DSR control output LVDS DSR may be set to the ON state or alternatively set to follow the state of the DCE supplied HSSI CA control input 3 1 4 Bit switch 4 This switch is not used on the BC1000 and should be set to the ON state for normal operation Bold characters Factory Default Serial No BC1000 EIA 644 LVDS CONVERTER AC Part Number 80 05 556 Metrodata Ltd TW20 8RY UK Tel 44 0 1784 744700 Fax 44...

Страница 11: ...ed when the LVDS DTE equipment does not provide a source synchronous LVDS TT signal 3 1 7 LVDS ST This switch is only used when the HSSI TT select is in the OFF state selecting LVDS ST as the source for HSSI TT At higher speeds the round trip delays introduced by the cable may be such that the data change is coincident with the data sample point Inverting ST will enable higher speed operation when...

Страница 12: ...or both Co Directional and Contra Directional LVDS operation For a Co Directional LVDS interface HSSI ST is passed transparently through the BC1000 The LVDS device will then use this clock to generate the LVDS along with the LVDS SD Send Data Data and Clock are then passed through Where the LVDS device does not return LVDS TT the BC1000 uses HSSI ST to sample the data from the LVDS device and to g...

Страница 13: ...D input OFF OFF ON Follow CTS and DCD ON ON OFF Follow LVDS DSR OFF ON OFF Follow DSR and CTS ON OFF OFF Follow DSR and DCD OFF OFF OFF Follow DSR and DCD and CTS Bold characters Factory Default Serial No BC1100 EIA 644 LVDS CONVERTER AC Part Number 80 05 557 Metrodata Ltd TW20 8RY UK Tel 44 0 1784 744700 Fax 44 0 1784 744730 For product manual and other information www metrodata co uk Manufacture...

Страница 14: ...switch set to the ON position the LVDS DTR is set ON With the switch in the OFF position the DTR control is set to follow the HSSI TA input 4 1 5 LVDS TT In order to support Contra Directional LVDS interfaces the source of the LVDS TT output is selectable With the bit switch set to the ON position the LVDS TT is sourced directly from the HSSI TT signal With the bit switch in the OFF position the i...

Страница 15: ... For a Co Directional LVDS interface LVDS ST is passed transparently through the BC1100 The HSSI device will then use this clock to generate the HSSI TT along with the HSSI SD Send Data Data and Clock are then passed through Where the LVDS device does not use LVDS TT the BC1100 uses LVDS ST to re time the data from the HSSI device and to generate the LVDS TT Contra Directional interfaces are depen...

Страница 16: ...hich may be used in this manual are hereby acknowledged Copyright 2006 by Metrodata Ltd All Rights Reserved EIA 644 Interface Definition Mode BC1000 DCE Presentation 25 way Female D type Mode BC1100 DTE Presentation 25 way Male D type HSSI Interface Definition Mode BC1000 DTE or BC1100 DCE Presentation Miniature 50 way Female connector General Definition Power supply 100 250 VAC 50 60 Hz 50 mA or ...