1. 将功能开关设置在所需的交流电流测试量程上。

2. 用钳表夹取待测导体,然后缓慢地放开板机,直到钳头完全闭合。

    注意:

    确保待测导体被夹取在钳头中央。钳表一次只能测量一个电流导体。若同时

    测量两个或两个以上的导体,则会产生错误读数。

3. 读取显示屏上的读数。

    注意:

    不要用手或皮肤接触任何裸露及带电导体。用钳表夹取待测导体前,必须事

    先从表上取下表笔。

交流电流测量

Содержание 05221

Страница 1: ...Digital Clamp Multimeter 05221 EN...

Страница 2: ...1 1 5 5 7 7 8 9 10 10 11 11 13 13 13 14 15 16 17 18 19...

Страница 3: ...05221 1 3 1 2 A D IEC 61010 2 CATIII 300V...

Страница 4: ...05221 2 1 2 3 4 5 6 7 8 30Vac 42Vac 60Vac 9 10...

Страница 5: ...05221 12 13 14 15 16 17 CATIII CAIV 3...

Страница 6: ...05221 4...

Страница 7: ...05221 1 1999 3 1 2 2 LCD 3 A D A D 5...

Страница 8: ...05221 4 LCD 1 5 3 6 1 7 AC 8 27mm 9 25mm 10 LCD 11 3V CR2032 3 12 0 C 40 C 75 13 20 C 60 C 85 14 151mm 65mm 34mm 15 127g 6...

Страница 9: ...05221 18 C 28 C 75 RH 9M 40Hz 400Hz 300Vrms 7 300V 1V 1 2 3 1...

Страница 10: ...05221 1 300V 8 9M 300Vrms 1 300V 300V 1V 1 0 2 1...

Страница 11: ...05221 9 AC 50 60Hz 400A 1 400A 20A 10mA 3 0 5 200A 100mA 400A 1A 2 5 5 1 1 1...

Страница 12: ...05221 10 1mV 3V 2000 200k 1 100 1 2 2 1 5 2 1...

Страница 13: ...05221 1 2 3 3 1 2 1999 11 1 30...

Страница 14: ...05221 4 COM 5 V 6 7 LCD HOLD HOLD 12 1 2 3 4 5 6 7...

Страница 15: ...05221 13 1 COM V 2 300V 3 4 1 COM V 2 300V 3 4...

Страница 16: ...05221 14 1 2 3...

Страница 17: ...05221 15 1 COM V 2 2000 200k 3 2000 30...

Страница 18: ...05221 16 1 COM V 2 3 LCD mV 1 COM V 2 3 30...

Страница 19: ...05221 17 3V CR2032 3...

Страница 20: ...05221 18...

Страница 21: ...Y SAFETY INFORMATION CAUTION ELECTRICAL SYMBOLS GENERAL DESCRIPTION GENERAL SPECIFICATION SPECIFICATIONS AC Voltage DC Voltage AC Current Resistance Audible Continuity Diode Test FRONT PANEL 1 1 5 6 7...

Страница 22: ...INSTRUCTION Measuring DC Voltage Measuring AC Voltage Measuring AC Current Measuring Resistance Measuring for continuity Measuring Diode BATTERY REPLACEMENT GENERAL MAINTENANCE ACCESSORIES 14 16 16 17...

Страница 23: ...id will be repaired adjusted or replaced at no charge to the original purchaser This warranty does not cover expandable items such as batteries or fuses If the defect has been caused by a misuse or ab...

Страница 24: ...eads for continuity Replace damaged test leads before you use the meter Do not use the meter if it operates abnormally Protection may be impaired When in doubt have the meter serviced Do not operate t...

Страница 25: ...attery door or measure AC current Do not operate the meter with the battery door or portions of the case removed or loosened To avoid false readings which could lead to possible electric shock or pers...

Страница 26: ...in the building installation Examples are measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and eq...

Страница 27: ...ower and discharge all high voltage capacitors before testing resistance diode and continuity Use the proper function and range for your measurements Before moving the rotary switch to change function...

Страница 28: ...ternating current Caution risk of danger refer to the operating manual before use Caution risk of electric shock Earth ground Terminal Conforms to European Union directives The equipment is protected...

Страница 29: ...operate and are ideal instruments GENERAL SPECIFICATION Display 3 1 2 digit LCD with a max reading of 1999 Sampling rate Approximate 3 times per sec Error caused by improper position 1 of reading Not...

Страница 30: ...ge temperature 20 C 60 C 85 RH Size 151mm X 65mm X 34mm Weight about 127g including battery SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 C 28 C with relati...

Страница 31: ...wave Frequency range 40Hz 400Hz Max permitted input voltage 300Vrms 1 If the voltage being measured is 300V the display may show the value of the voltage but the measurement is dangerous Range Functi...

Страница 32: ...permitted input voltage 300Vrms 1 If the voltage being measured is 300V the display may show the value of the voltage but the measurement is dangerous Range Functions Resolution 300V 1V 1 0 2 Accuracy...

Страница 33: ...owable input current 400A 1 If the current being measured is 400A the display may show the value of the current but the measurement is dangerous 20A 10mA 3 0 5 200A 100mA 400A 1A 2 5 5 1 shown on disp...

Страница 34: ...dication 1 shown on display Resistance Range Resolution The built in buzzer will sound If the resistance is less than about 30 Description Continuity test Functions 1 Range Resolution Approx forward v...

Страница 35: ...o get more accurate reading the conductor should be in the center of the jaws 2 Trigger Used to open and close the jaws for AC current measurement 3 Display 3 1 2 digit LCD with a max reading 1999 4 C...

Страница 36: ...ay as an indicator To exit Data Hold mode just press this button again HOLD disappears OPERATING INSTRUCTION Measuring DC Voltage Insert the plug of the black test lead to the COM jack the plug of the...

Страница 37: ...o position Connect the test leads across the source or circuit to be tested Read the voltage value on the LCD Measuring AC Current Set the rotary switch to the desired AC current range position Press...

Страница 38: ...play Measuring Resistance Insert the plug of the black test lead to the COM jack the plug of the red test lead to the jack Set the rotary switch to the desired resistance range position 2000 or 200k C...

Страница 39: ...continuity Insert the plug of the black test lead to the COM jack the plug of the red test lead to the jack Set the rotary switch to the position Connect the test leads across the load to be tested Wh...

Страница 40: ...olarity of the red test lead is Set the rotary switch to the position Connect red test lead to the anode of the diode black test lead to the cathode of the diode Read the approximate forward voltage o...

Страница 41: ...e battery door replace the exhausted batteries with new batteries of the same type 3V battery CR2032 or equivalent Refer to the figure the Plus side of the batteris must face up Rejoin the battery doo...

Страница 42: ...o not use abrasives or solvents Dirt or moisture in the jacks can affect readings Clean the jacks as follows Make sure that no object is clamped in the jaws Turn the meter off and remove all test lead...

Страница 43: ...e Test leads 1 pair NOTE 1 This manual is subject to change without notice 2 Our company will not take the other responsibilities for any loss 3 The contents of this manual can not be used as the reas...

Страница 44: ...177 3 201203 Tel 86 21 6061 1919 Fax 86 21 6061 1918 S A T A T O O L S H A N G H A I L I M I T E D Customer Service 3 F No 177 Bibo Road Shanghai 201203 UM_ET_05221_190508...

Отзывы: