![Saswell T21HTW-0 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/saswell/t21htw-0/t21htw-0_operating-instruction_1199981018.webp)
17
3
▼
bL (2)
1
– 3
Select display backlight (1) = OFF, (2) = 30
seconds on any button push, (3) = ON. Default
= 2.
Option (3) can be activated only if the common
is used.
4
▼
FL (00)
00, 1 thru12
Select filter time in months. Default = 00.
A selection of “00” deactivates the filter feature.
5
▼
FC (F)
F or C
°F or °C display. Default = F
6
▼
CL (0)
+4 TO -4
Select temperature calibration point up to 4°
higher or 4° lower. Default = 0
7
▼
CP (5)
0 or 5
Compressor Lockout delay. 0 = none, 1=1 Min
’;
2=2 Min
’; 3=3 Min’, 4=4 Min’, 5=5 Minutes
Default = 5
8
▼
AU (2)
2 or 10
Aux Heat offset , Default=2
2=
2º below “Y” on ;10=10º below “Y” on