Saswell SAS816WHB-0-RF Скачать руководство пользователя страница 2

 

 

2

In Wall Box 

Receiver Base

Front Cover

Screw

MOUNTING THE RECEIVER 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting the Receiver onto the optional wall box

 

(See Figure 4)

 

1.   

Remove assembly screws from the base of thermostat. Gently pull the upper housing straight off the 

base. Forcing or prying on the thermostat will cause damage to the unit. See figure 1. 

2.  Connect wires beneath terminal screws on the base using appropriate wiring schematic. See figure 2   

3.  Install two fresh 

AA

 alkaline batteries in battery compartment. Be sure to match positive (+) ends 

of batteries with positive (+) battery terminals in the battery compartment. See figure 3 

4.  Push power base into wall. 

5.  Using mounting screws mount the power base to the wall. Place a level against bottom of base, 

adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect 

thermostat operation.) 

6.  Replace the upper housing on the base and fix the upper housing by removed assembly screw 

 

WIRING DIAGRAM 

 

 

 

 

 

 

Figure 5 

 

SWITCH AND LED DESCRIPTION OF RECEIVER 

 

Figure 4 

L

L

N

2

1

1

2

3

N

L

Heat On

4 5

Heat Off

COM

NC

5

4

For Volt Free Application

The unit still requires a 230V feed

NO

3

For 230VAC Application

POWER  SWITCH:

  When  there  is  no  demand  to  turn 

on the heating/cooling device, it is recommended to turn 

the power switch to the off position. 

LED INDICATOR: 

1.  Red  LED  turns  on  as  long  as  there  is  power  to  the 

unit 

2.  Green  LED  turns  on  as  long  as  the  heating/cooling 

device is energized. 

3.  Yellow LED flashes as long as there are any signals 

received from the Control Centre. 

Figure 6 

RXD ON POWER

ON

OFF

LED

LED

LED

POWER SWITCH

LED INDICATIORS