PDP-503CMX
102
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Input Signal
Adjusting Point
Adjusting Method
White 100%
REF_DIG mode
in Factory mode
X-SUS-B : key 9
Y-SUS-B : key 11
X-SUS-B, Y-SUS-B Adjustment
Set to the indicated value with the keys on the remote control unit (9 and 11 keys).
Input Signal
Adjusting Point
Adjusting Method
White 100%
VR3701 (VRN)
(X DRIVE Assy)
VRN (minus reset voltage adjustment)
Adjust so that the voltage between K3707 (VRN) and K3702 (SUS-GND) becomes
-300V
±
1.0V.
VIDEO OPTION mode in
Factory mode
SIDE MASK LEV.
R SIDE LEVEL : key 1
G SIDE LEVEL : key 2
B SIDE LEVEL : key 3
Side mask color / Level Adjustment
Set the indicated value with the keys on the remote control unit (1, 2 and 3 keys).
Input Signal
Adjusting Point
Adjusting Method
Input Signal
Adjusting Point
Adjusting Method
Reference : Adjustment values when using the Minolta color-difference meter (A-100)
Adjust the OFFSET-DIGITAL parameters (from PANEL R-HIGH to PANEL B-LOW) in Factory
mode.
For adjustment, use the mask (MASK04) signal of Factory mode for display.
Sustain Pulse Waveform Adjustment
VRN Voltage Adjustment
Panel-White-Balance Adjustment
Mask-Level Adjustment
MASK Left Side
x
295
y
306
MASK Right Side
291
300
Содержание AED-5001
Страница 11: ...PDP 503CMX 9 5 6 7 8 5 6 7 8 C D F A B E...
Страница 160: ...PDP 503CMX 158 1 2 3 4 1 2 3 4 C D F A B E Pin Assignment Top view CXA3516R RGB ASSY IC4603 AD PLL IC...
Страница 161: ...PDP 503CMX 159 5 6 7 8 5 6 7 8 C D F A B E Block Diagram...
Страница 162: ...PDP 503CMX 160 1 2 3 4 1 2 3 4 C D F A B E Pin Function 1 3...
Страница 163: ...PDP 503CMX 161 5 6 7 8 5 6 7 8 C D F A B E Pin Function 2 3...
Страница 164: ...PDP 503CMX 162 1 2 3 4 1 2 3 4 C D F A B E Pin Function 3 3...