Getting Started

Remove the scale, load plate
and AC adapter from the
package.
Immediately after unpacking the
equipment, check it for any
visible damage.

Equipment Supplied:

Scale, load plate,
AC adapter, data cable
(25-pin - 9-pin)

Do not miss out on the benefits
of our full warranty.  Please
contact your local Sartorius
office or dealer for further
information.  If available,
complete the warranty
registration card, indicating the
date of installation, and return
the card to your Sartorius office
or dealer.

Choose a suitable place to set up the scale.  Avoid exposure to
drafts, heat, moisture and vibration.

Check that the voltage rating of the AC adapter matches that

of your local line voltage (mains supply).  If it does not match your
local line voltage, contact your Sartorius office or dealer.  Use
only original Sartorius AC adapters!  If you operate the scale in a
hazardous area/location outside Germany, you must comply with
the national electrical code and applicable safety regulations of
your country.  For information on the legal regulations currently
applicable in your country, please ask your Sartorius office or
dealer or your paint supplier.

The model 609308... AC adapter must be installed outside

the hazardous area/location.

Before you operate your scale in a hazardous area/location,

the scale must be inspected either by a certified electrician or
under the guidance and supervision of a certified electrician to
make sure that the scale complies with the applicable regulations
(in Germany, in accordance with Section 12 of the ElexV).
Determine whether your scale must be reported to the technical
inspection authorities (e.g., trade board) in your country.  The
system must also be inspected during operation.  The system should
be inspected at intervals which allow for early detection of the
faults which occur as a result of normal wear and tear, so that they
can be corrected before damage is caused.  In any case,
inspection must be performed at least every three years.

Fasten the AC adapter cable to the balance.  Tighten down the

locking ring to secure the connection.  Do not disconnect an
energized cable during operation in a hazardous location/area.

All applicable requirements (e.g., occupational safety

regulations) must be observed during operation.

Any tampering with the equipment by anyone, other than repair

work done by authorized Sartorius service technicians, will
invalidate the approval for use in hazardous areas/locations and
result in forfeiture of all claims under the manufacturer’s warranty.

Содержание Sartorius PMA 35D-X

Страница 1: ...98648 008 38 Sartorius PMA 35D X PMA 35D X00C PMA 35D X00CV1 Electronic Paint Mixing Scales Installation and Operating Instructions...

Страница 2: ...Note to Users G Make sure to carefully read and follow sections marked with this symbol They contain important safety instructions and information G Use only the adapter that is included in delivery...

Страница 3: ...09308 AC adapter must be installed outside the hazardous area location G Before you operate your scale in a hazardous area location the scale must be inspected either by a certified electrician or und...

Страница 4: ...ut 1 with the wrench Replace the load plate Ground the scale in the hazardous area location Connect an equipotential bonding conductor to the terminal 11 After connecting the scale to AC power wait ap...

Страница 5: ...before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the key 4 for 2 sec When 5000 is displayed release the key Center the calibration weight on the load plate 1 C...

Страница 6: ...00C Only Let s suppose that you poured in too much of one color component for a given formula e g with 4 components In addition let s assume that you previously poured in all of the other amounts exac...

Страница 7: ...in too much The correct weight for the formula is 200 0 g 8 Press the y key 10 to start the recalculation mode A C correct flashes on the display 9 Press the y key 10 to correct the value to 200 0 g...

Страница 8: ...able conditions 1 1 4 To obtain a detailed list of the menu codes please ask your nearest Sartorius office dealer or paint supplier Care and Maintenance Cleaning Use only naphtha or alcohol to clean t...

Страница 9: ...ill of paint Please enclose a description of the equipment failures faults C Marking Note G The seal marking affixed to the equipment indicates that the equipment may be opened and serviced only by te...

Страница 10: ...40 Power consumption VA average 8 Interface RS 232C Format 7 bit ASCII 1 start bit 1 or 2 stop bits Parity odd even mark or space Transmission rates 150 to 9600 baud Handshake Software or hardware Po...