Installation Instructions

Your balance/ scale is designed to 
provide reliable weighing results under
normal ambient conditions.  W hen
choosing a location to set up your
balance/ scale, observe the following
so that you will be able to work with
added speed and accuracy:

Set up the balance/ scale on 
a stable, even surface
Avoid placing the balance/ scale 
in close proximity to a heater or
otherwise exposing the balance/
scale to heat or direct sunlight
Protect the balance/ scale 
from drafts that come from open
windows or doors
Avoid exposing the balance/ scale
to extreme vibrations during 
weighing
Protect the balance/ scale from 
aggressive chemical vapors
Do not expose the balance/
scale to extreme moisture over long
periods

Conditioning the Balance/ Scale: 
Moisture in the air can condense 
on the surfaces of a cold balance/
scale whenever it is brought into a
substantially warmer place.  If you
transfer the balance/ scale to a 
warmer area, make sure to condition it
for about 2 hours at room temperature,
leaving it unplugged from AC power.

Information 
on Radio Frequency Interference

Warning!

This equipment generates, uses and
can radiate radio frequency energy
and, if not installed and used in 
accordance with the instruction 
manual, may cause interference to
radio communications. It has been
tested and found to comply with the
limits for a Class A computing device
pursuant to Subpart J of Part 15 of 
FCC Rules, which are designed to 
provide reasonable protection against
such interference, when operated in a
commercial environment. Operation of
this equipment in a residential area is
likely to cause interference, in which
case the user, at his own expense, will
be required to take whatever measures
may be required to correct the 
interference.

Содержание BL310

Страница 1: ...INSTRUCTION MANUAL Balance Model BL310 Brand...

Страница 2: ...SartoriusBasiclite Series SartoriusGemlite Series Electronic Precision Balances and Precious Metal Scales Operating Instructions 98648 008 55...

Страница 3: ...otal Formulation Second T are Memory 16 T oggle Between Weighing Units 17 Configuring the Balance Scale Setting the P arameters Menu Codes 18 Balance Scale Operating Menu Overview 19 Error Codes 20 C...

Страница 4: ...chapter entitled Care and Maintenance under the section on Safety Inspection Save the box and all parts of the packaging until you have successfully installed your balance scale Only the original pac...

Страница 5: ...e air can condense on the surfaces of a cold balance scale whenever it is brought into a substantially warmer place If you transfer the balance scale to a warmer area make sure to condition it for abo...

Страница 6: ...chamber in the order given Draft shield base place it on the balance so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place Pan support Weighing pan...

Страница 7: ...M1502 A non rechargeable or rechargeable battery is not included with the equipment supplied Use only a commercially available non rechargeable or rechargeable 9 volt battery W hen using a rechargeabl...

Страница 8: ...ce scale any time you set it up in a new location Use only the 2 front feet of the balance scale for leveling T urn the 2 rear feet until they are in position only on models BL 1500S and GM1502 T urn...

Страница 9: ...le T o load factory set configurations See Configuring the Balance Scale parameter 9 1 T o tare the balance scale Press t Additional Functions T o turn off the balance scale Press e Example Basic weig...

Страница 10: ...1 4 1 Example Calibrate the balance scale Menu code settings Factory set codes Step Key or instruction Display Printout 1 T urn on the balance scale e 2 T are the balance scale t 0 0 g 3 Begin calibra...

Страница 11: ...Scale The average piece weight is automatically output via the optional data interface port after initialization if the menu code for Printout with data ID codes is set Press v to toggle the display b...

Страница 12: ...he balance scale t 0 0 g 13 Display the reference sample v 2 sec r ef 20 briefly quantity here 20 pcs 14 Place the reference sample 66 0 g quantity 20 pcs on the balance scale here 66 g 15 Start the a...

Страница 13: ...lance Scale The reference percentage is automatically output via the optional data interface port after initialization if the menu code for Printout with data ID codes is set Press v to toggle the dis...

Страница 14: ...ale e 12 T are the balance scale t 0 0 g 13 Display the reference percentage v 2 sec r ef 100 14 Place the reference weight 222 50 g for 100 on the balance scale here 222 5 g 15 Start application if t...

Страница 15: ...culated value Y ou can set the number of subweighing operations performed in the operating menu See Configuring the Balance Scale Press v for at least 2 sec to display the preset number of subweighing...

Страница 16: ...out 1 T urn on the balance scale e 2 T are the balance scale t 0 0 g 3 Display the number of subweighs here 10 v 2 sec r ef 10 briefly 4 Place sample on the balance 8888 scale weight readout fluctuate...

Страница 17: ...ction Display Printout 1 T urn on the balance scale e 2 Place an empty container on 65 0 g the balance scale 3 T are the balance scale t 4 Add the first component 120 5 g 5 Store the first component w...

Страница 18: ...ozt 1 7 8 3 1 8 Hong Kong taels 0 02671725000 tlh 1 7 9 3 1 9 Singapore taels 0 02645544638 tls 1 7 10 3 1 10 T aiwanese taels 0 02666666000 tlt 1 7 11 3 1 11 Grains 15 43235835000 GN 1 7 12 3 1 12 Pe...

Страница 19: ...ments are displayed t briefly 1 T o navigate within a menu t 2 level the last menu option is repeatedly followed by the first option 9 1 3 Select the 2nd menu level p 1 1 4 Select the 3rd menu level p...

Страница 20: ...am programs description 3 Application 3 1 Weight unit 2 see T oggle between Weight Units parameters 3 3 R eference qty or see the desired application program description 5 through 7 appliesonly if an...

Страница 21: ...tare the balance scale balance scale isloaded Unload the balance scale e 09 W hen gross value zero no tare T are the balance scale e 10 The t key is blocked when P ress c to clear the there is data in...

Страница 22: ...ined persons to perform repairs may lead to hazards for the user Cleaning Disconnect the balance scale from the AC adapter and unplug any interface cables that are connected to the balance scale Make...

Страница 23: ...vice Center or the International T echnical Support Unit based in Goettingen Germany Maintenance and repair work may only be performed by service technicians who are authorized by Sartorius and who ha...

Страница 24: ...nds on the filter level selected s 0 1 0 4 External calibration weight g 200 E2 100 E2 50 E2 100 F1 1000 F2 of at least accuracy class lb 0 4 E2 0 2 E2 0 1 E2 Net weight approx kg lb 3 0 6 6 3 0 6 6 3...

Страница 25: ...selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight g 100 F 1 1000 F 1 500 F2 100 F2 100 F2 100 M1 5000 F2 of at least...

Страница 26: ...n to ambient conditions By selection of 1 of 4 optimized filter levels Display update depends on the filter level selected s 0 2 0 8 External calibration weight kg 1 F2 1 M1 0 5 M1 5 M1 5 M1 1 M1 of a...

Страница 27: ...e required Carrying case for modelswith a readability 1mg YDB01BL for modelsBL 210S BL 120S BL 60S YDB02BL Product Order No Dust cover for use during weighing for models with a rectangular weighing pa...

Страница 28: ...rtorius and must check and if necessary correct these modifications and connections On request Sartorius will provide information on the minimum operating specifications in accordance with the Standar...

Страница 29: ...rm or by any means without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG...

Отзывы: