Utilities for Printouts or Data Transfer: 

 
Sartorius Balances come Standard with an interface. 
You can plug a Sartorius Printer or a Computer into this interface port to print data on hard copy or transfer 
them to your Computer. Moreover, you can choose to Output data from your balance to this on-line device 
either automatically or by pressing the print key on the balance. 
The balance operating menu lets you define the various parameters for data Output. 
For information on the data formats and for interfacing a Computer or a different peripheral device, see "In-
terface Description." 
 
 

Data Output Parameter 

 
This parameter is coupled with or without the stability parameter = stable readout or no motion is detected 
Print on request = data is Output only when the print key is pressed or a Software command is received 
Auto print = continuous, automatic data output 
 
 Code 

Changes 

Print on request regardless of stability 

6  1  1 

 

Print on request after stability with storage of the  
function 

6  1  2 

 * 

Print on request after stability without storage of the  
function 

6  1  3 

 

Auto print regardless of stability 

6  1  4 

 

Auto print at stability 

6  1  5 

 

 
 

Data Output in Defined Intervals 
 

You can reduce the volume of data in the "auto print" mode by defining the interval at which data will be Out-
put automatically. This auto print interval is based on the number of times the display is updated. 
 
Auto print interval 

Code 

Changes 

1 display update 

6  3  1 

 * 

2 display updates 

6  3  2 

 

 
 
 

Data ID Codes 
 

An 

"N"

 printed or displayed before a weight identifies it as a net weight. 

This ID code increases the data output format for each value from 16 to 22 characters. 
 
ID code for data output 

Code 

Changes 

Without 

7  2  1 

 * 

With 

7  2  2 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

= factory setting, depends on balance model in some cases 

Содержание BA 110

Страница 1: ...Sartorius Basic Electronic Analytical and precision Balances Installation and Operating Instructions 98648 002 63...

Страница 2: ...2 BA 210 S BA 160 P BA 110 S...

Страница 3: ...3 BA 310 S BA 310 P...

Страница 4: ...4 BA 110...

Страница 5: ...5 BA 210...

Страница 6: ...6 BA 4100 S BA 3100 P BA 2100 S BA 610 BA 6100 BA 4100 BA 2100...

Страница 7: ...base plate 17 Data interface depends on type of model 7 Locking ring depends on type of model 18 AC jack 8 Leveling foot depends on type of model 19 Manufacturer s label on bottom of balance 9 Menu a...

Страница 8: ...Weighing 21 How to Fasten an Antitheft Locking Device 21 Special Functions Operating Parameters Balance Operating Menu 22 Weighing Mode Adaption to Ambient Conditions 22 Stability Range 22 Tare Param...

Страница 9: ...ge temperature 40 C 70 C 40 F 158 F The packaging has been designed to ensure that the balance will not be damaged even if it is dropped from a height of 80 cm maximum about 32 inches Carefully unpack...

Страница 10: ...ance Balance AC adapter AC adapter AC adapter AC adapter Weighing pan Weighing pan Weighing pan Weighing pan Pan support Pan support Pan support Glass cylinder of the round draft shield Protective rin...

Страница 11: ...balance may not be used in a hazardous location area where there is danger of explosion Do not expose the balance to extreme moisture over long periods Moisture in the air can condense on the surface...

Страница 12: ...t shield on the balance Take the base plate out of the weighing chamber Align the draft shield Position the locking ring 7 in the weighing chamber and turn it clockwise until it locks in place Install...

Страница 13: ...nstall the following parts on the balance in this order pan support 3 weighing pan 1 glass cylinder of the round draft shield 21 draft shield lid 20 Starting Up the BA 110 Place the draft shield base...

Страница 14: ...ease contact your Sarto rius dealer or Office Important Note Only use original Sartorius AC adapters identified by the Sartorius la bel Use of AC adapters from other manufacturers even if these units...

Страница 15: ...adapter rated to Class 2 can be plugged into a wall outlet without taking any additional safety precautions The pole of the output voltage is connected to the balance housing which can be grounded fo...

Страница 16: ...ould utilize our antistatic pan 130 mm see Accessories instead of the Standard weighing pan Leveling the Balance Using the Level Indicator depends on type of model At the point of use level the balanc...

Страница 17: ...ilure or out age for longer than approx 3 seconds reconnection to AC power after the balance was unplugged Standby The display has been turned off with the ON OFF key 16 and the balance is now in the...

Страница 18: ...0 00 g 0 000 g or 0 0000 g depending on the balance model Taring For exact weight determination press the tare control 15 to zero the weight display You can tare within the entire weighing range of t...

Страница 19: ...ap pear briefly In this case tare the balance and press the CAL key again once you obtain a zero readout Center the calibration weight on the weighing pan The balance calibrates itself automatically...

Страница 20: ...ector into the interface port Secure the interface connector by tightening the screws Important Note Make sure to unplug the AC adapter from the wall outlet before you connect or disconnect additional...

Страница 21: ...ch the closing plate Now you can attach a sample using a Suspension wire for example Common applications for below balance weighing include specific gravity determination or immersing a sample in a sp...

Страница 22: ...is adapted to ambient conditions by changing the time allowed for weighings see the Product Data Sheet Code Changes Very stable environment shortest measuring time 1 1 1 Stable environment short measu...

Страница 23: ...wn on the balance display this applies to code numbers ending with 8 tlh 9 tls 10 tlt 14 lb 15 tlc 16 mom 17 K 18 tol 19 bat 20 MS Calibration Function Code Changes Calibration with standard calibrati...

Страница 24: ...ed on automatically after a power failure has occurred or after you have disconnected your balance temporarily from AC power In the setting automatic power on the balance will automatically turn on ag...

Страница 25: ...is pressed or a Software command is received Auto print continuous automatic data output Code Changes Print on request regardless of stability 6 1 1 Print on request after stability with storage of th...

Страница 26: ...umbers the series will start again from 0 T 15 confirm settings store them and exit the menu 14 move to the right and left Now please try it for yourself turn off the beeper tone acoustic Sig nal code...

Страница 27: ...confirm the code setting You must press the tare control 15 to confirm the code you have just set this is indicated by o after the code use the key to move to the left digit press the tare control 15...

Страница 28: ...nt code setting is displayed This makes it easy to check the codes you have set How to Undo All Menu Code Changes Reset Function The reset function lets you undo all menu code changes which means you...

Страница 29: ...e weight readout changes con stantly Unstable ambient conditions Too much Vibration or the bal ance is exposed to a draft The draft shield is not completely closed A foreign object is caught be tween...

Страница 30: ...afe Operation of the balance with the AC adapter is no longer en sured when there is visible damage to the AC adapter the AC adapter no longer functions properly the AC adapter has been stored for rel...

Страница 31: ...1986 in conjunction with Article 10 of the Low Voltage Directive 73 23 EEC issued on February 19 1973 by the European Community it is hereby certified that the equipment delivered Electronic Analytica...

Страница 32: ...te time and statistics functions Print speed approx lines sec 1 5 Printer housing B x T x H in mm 150 x 138 x 43 Remote display can be plugged into the interface port of the balance LCD reflective 737...

Страница 33: ...ance can also tell when it is being powered by line current provided the AC adapter is plugged in and the line current supply is intact If you utilize the battery pack the code for automatic shutoff 8...

Страница 34: ...terface cable adapter 25 position to 9 position Specific gravity determination set for BA 210 S BA 160 P and BA 110 S YDK 01 Antistatic weighing pan for balances with 0 1 mg readability YWP 01 BA Anal...

Страница 35: ...ure range o C 10 30 Sensitivity drift within 10 30 o C C o 2 10 6 3 10 6 2 10 6 2 10 6 Moisture proof rating according to DIN 40 040 Class F non condensing Pan size mm 80 W geraumh he mm 200 Net weigh...

Страница 36: ...hin 10 30 o C C o 2 10 6 5 10 6 2 10 6 Moisture proof rating according to DIN 40 040 Class F non condensing Pan size mm 130 130 80 Net weight approx kg 4 5 4 5 3 5 Selectable weight units g kg ct lb o...

Страница 37: ...within 10 30 o C C o 2 10 6 5 10 6 2 10 6 5 10 6 Moisture proof rating according to DIN 40 040 Class F non condensing Pan size mm 175 x 175 Net weight approx kg 3 9 3 3 3 Selectable weight units g kg...

Страница 38: ...rating according to DIN 40 040 Class F non condensing Pan size mm 116 175 x 175 175 x 175 175 x 175 Net weight approx kg 1 6 3 3 1 6 Selectable weight units g kg ct lb oz ozt tlh tls tlt GN dwt mg lb...

Страница 39: ...39 Dimensions Scale Drawings Note All dimensions are given in millimeters...

Страница 40: ...40 Dimensions Scale Drawings Note All dimensions are given in millimeters...

Страница 41: ...41 Dimensions Scale Drawings Note All dimensions are given in millimeters...

Страница 42: ...Copyright by Sartorius AG G ttingen Deutschland All rights reserved No part of this publication may be printed or translated in any form or by any means without the prior written permission of Sartori...

Отзывы: