For installation assistance, contact SARGENT at 800-810-WIRE (9473)
A7877A
© SARGENT Manufacturing Company 2007
7
Profile Series H1 Mortise Lock
1. Securely tighten lockbody screws on the edge of the door and
then securely tighten the thru bolt screws.
2. Connect P3 (2 Pin Connector) from lock body to J3 on Interior
Escutcheon PCB Assembly.
3. Connect P4 (5 Pin Connector) from lock body to J4 on Interior
Escutcheon PCB Assembly.
4. Connect P5 (7 Pin Connector) from Reader board to J5 on
Interior Escutcheon PCB Assembly.
5. Connect E-Lynx Harness (4 Pin & 8 Pin) from door harness to
E-Lynx harness on Interior Escutcheon PCB Assembly.
6. Place extra wire inside door hole
NOTE: Connectors go on only one way. Do not offset connector
and be sure they are completely seated.
Step #5 – Installation of Outside Escutcheon Reader & Lever Assembly
1. Feed the reader cable connector located on the back of the outside escutcheon from the outside of door
through door.
2. Securely tighten the outside escutcheon with (2) through-bolts (#8-32 x 2") Phillips flat head screws with the
mounting plate.
3. With outside lever horizontal, insert the mounting post through outside of door and lock body. Make certain
the lever spindle is proper engaged in lock.
4. On the inside of the door, insert spindle into square hole of mortise lock.
5. Slide inside adapter and plate assembly over spindle and loosely secure with (2) screws (#8-32 x 5/8"). Do not
tighten completely, cylinder should be installed prior to tightening.
Note: For 82276 & 82278, thread cylinder through escutcheon and into the lockbody.
Step #6 – Connector Attachment
Escutcheon Screws
#8-32 x 2" long
Phillips Flat Head
#8-32 x 5/8"
Machine Screws
Reader Cable
Gasket Outside Harmony - Mortise
J5
J5
J4
J4
J3
J3
To E-Lynx
Harness
From Reader Board
P5 to J5
From Lock Body
P3 to J3
From Lock Body
P4 to J4