![Sargent and Greenleaf 3006-2 Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/sargent-and-greenleaf/3006-2-series/3006-2-series_programming-and-operations-manual_1199155028.webp)
Page:28
3.34
—
Command 90: Display Lock Serial Number
This command will allow the user to view the lock serial number on the display.
Step 1 Enter: 9 0 *
3
.
35
—
Command 96: Check Battery Level
Lock Serial
12345678
This command will allow the user to check the estimated battery level. An icon will show the approximate
battery level of the unit.
Step 1
Enter: 9 6 *
OR
OR
3
.
36
—
Command 97: Display Time & Date
This command will allow the user to view the lock
’
s time and date on the display.
Step 1
Enter: 9 7 *
4
.
SERVICE MODE OPERATION
4
.
1
—
Service Mode Initialization (Single and Multiple)
27/05/2017
15:47
To successfully operate the lock in Service Mode, the lock must first be initialized. A keypad extension with touch key
reader must be connected to the lock. Lock initialization requires a management touch key prepared by the primary
service
company’s
Lock Management Software (LMS) system. This touch key will have been prepared for either single or
multiple mode. It is important for the key provider to advise which mode is being used to whoever is performing
initialization at the lock.
The management touch key is used in conjunction with a keypad command to initialize the lock. Lock initialization can only
be completed after the date and time are set using the procedures outlined previously in this document. If initialization is
attempted before time and date are set, the lock will sound two sets of 2 long beeps (braps). Always use local standard
time at the
lock’
s location. (If the lock is located in an area that observes daylight savings time and daylight savings time is
presently being observed, the time must be adjusted back one hour in the l
ock’
s settings).
To initialize a single lock (Command 54):
Step 1
Set the date & time using the appropriate procedures.
Step 2
Snap the Management touch key into the keypad extension receptacle.
Step 3
5 4 * 0 1 2 3 4 5 6 #
♪♪♪♪♪
Step 4
The yellow LED will remain lit during the initialization process. This process will take up to 90
seconds to complete.
Step 5
Upon successful initialization, the green LED will flash and the keypad will emit three
beeps. If the initialization fails for any reason, the red LED will flash and the lock will emit
one long beep.
Enable Service
Enter Code
********
100
0