background image

 

Sarasota Quality Products • 

27330 Center Ridge Road •Westlake • Ohio 44145 

Ph: (440) 899-9820 

 Fx: (440) 899-0930 

 www.sarasotaqp.com

 

3

 
 
 
 
 
 
 
 
 
CONFIGURING THE SYSTEM OR REPLACING A TRANSMITTER. 

 
Remote Float™ Transmitters are configured to the Key Captain control 
unit at time of assembly or whenever a new transmitter is purchased.  
Each control unit will need to be configured (learn) about all the 
transmitters before the system will function.  

1. 

To configure the system apply power the control panel (see 
wiring instructions). 

2. 

Press the plunger of the learn switch located on the control 
panel.  This will place the control panel in the learn mode and 
will disable the lock/unlock features from operating. 

3. 

With the control panel in the learn mode, press the lock button 
on the transmitter for one second and release. 

4. 

Wait one second then press the lock button again, but hold 
and do not release. 

5. 

The lock/unlock system will continue to be inoperable and will 
not respond to the transmitter for another 10 seconds. 

6. 

Once the control panel has learned about the transmitter it will 
respond to the transmitter and actuate the lock/unlock system. 

7. 

The control panel has learned about the transmitter and can 
be used.  

8. 

Repeat steps 1-8 to configure additional transmitters. 

 

 
 

 

 
 

 
 
 
 

KEY CAPTAIN™ SLEEP MODE 
 

The Float Remote™ will put itself into a power saving “sleep mode” 
when inactive for several minutes.  It will reactivate when any 
pushbutton is pressed. 
 

KEY CAPTAIN™ AUDIBLE MODE 

 

Each time a Float Remote™ pushbutton is pressed the control 
panel will produce an audible “chirp’ to acknowledge to the operator 
that the transmitted signal has been received.  The audible may be 
permanently disabled by clipping the jumper wire on outside of 
control panel case. 
 
 

 

 
 
 

To permanently disable audible signal, 
cut jumper wire. 

 
 
 
 

 
 

Содержание Key Captain

Страница 1: ... on wire connectors for 12 16 18 gauge wire Cable tie wraps Suitable stainless steel pan head screws Fuses as required Fuse holder for above fuses 12 16 18 gauge wire INSTALLATION MUST MEET APPLICABLE SECTIONS OF TITLE 33 CFR 183 SUBPART I USCG REGULATIONS To prevent personal injury always disconnect the battery leads when installing the control panel electric lock latches or connections to auxili...

Страница 2: ...ibution panel to Key Captain electrical lock latches Observe polarity of wiring to connect to all light blue wires see Fig 3 6 Connect unlock white control panel circuit wire from fuse distribution panel to Key Captain electrical lock latches Observe polarity of wiring to connect all white wires together see Fig 3 7 Connect trim down pink control panel circuit wire from fuse distribution panel to ...

Страница 3: ...elease 4 Wait one second then press the lock button again but hold and do not release 5 The lock unlock system will continue to be inoperable and will not respond to the transmitter for another 10 seconds 6 Once the control panel has learned about the transmitter it will respond to the transmitter and actuate the lock unlock system 7 The control panel has learned about the transmitter and can be u...

Страница 4: ...Sarasota Quality Products 27330 Center Ridge Road Westlake Ohio 44145 Ph 440 899 9820 Fx 440 899 0930 www sarasotaqp com 4 ...

Страница 5: ...Sarasota Quality Products 27330 Center Ridge Road Westlake Ohio 44145 Ph 440 899 9820 Fx 440 899 0930 www sarasotaqp com 5 ...

Страница 6: ...erates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off ...

Отзывы: