3. Parameter adjustment

Only under non-working status (when the READY button is blue), the parameters can be adjusted and the 
hand piece can be chosen. The “+”, “-” button is for adjustment.

After the parameters are adjusted, if you change the hand piece, or press the “BACK” button, the 
parameters will return back to initial value.

 

4. Working status

Set all the parameters, press the “READY” button, the device will enter into a working status. The 
“READY” button will turn yellow and there will be a progress bar for the hand piece.

Then press the pedal and the treatment will start. During the treatment, the time parameters will start a 
count down. When the time is 00:00, it will sound an alarm and the treatment will be complete.

5. The machine and parameter status

On the left side of the interface, it will show the device status and parameters of current hand piece 
(temperature, air pressure etc.)

Device status: SETTING, READY, WORKING and other alarm information. SETTING is before starting  
the machine, the parameters can be adjusted. READY is when the machine is starting, but the pedal is  
not working.

WORKING is when the machine has started and the pedal is working at the same time.

If it shows other status information, this means that the machine has something wrong and it cannot go 
back to working status. Please turn off the power supply and restart the device. If the device still does not 
work, please contact the manufacturer.

6. Software update

When the machine is in network mode and there is a new software version available, you will get an 
update indication.

SETTING

D1                                      0

o

C

Содержание Magic Eyes

Страница 1: ...U S E R M A N U A L...

Страница 2: ......

Страница 3: ...CONTENTS 4 PRODUCT DESCRIPTION 4 PRODUCT COMPONENTS 4 MAIN COMPONENTS 5 SYSTEM PARAMETERS 5 HAND PIECE INTRODUCTIONS 6 PCS 8 OPERATION INTRODUCTIONS 10 TREATMENT INTRODUCTIONS 11 PLEASE NOTE...

Страница 4: ...ch Qty 1 2 AC Power Cable Qty 1 3 Annular inlet D1 Handle Qty 1 4 Ball inlet D2 Handle Qty 2 5 Single polar cooling radio frequency S1 Handle Qty 1 6 Bio polar vacuum radio frequency S2 Handle Qty 1 7...

Страница 5: ...AMETERS HAND PIECE INTRODUCTIONS 6 PCS Parameter Values LCD Touch Screen 15 6 inch Vacuum Pump Life Time 20 000 hours Input VAC 100 260VAC 50 60Hz Input AC Power 600W Dimension Approx 42x28x20cm Weigh...

Страница 6: ...ND PIECE OVAL HEAD INLET 2 PCS HEATING MASSAGE RING HEAD ELECTRICAL INFUSION Diameter 20mm Length 180mm Dimeter of electrode 10 2mm Electricity 0 0 3mA Temperature 25 45 C Preset temperature 35 C Temp...

Страница 7: ...al distance of polars 10 2mm Length 220mm Max pressure of vacuum 70KPa Power Max 10W Frequency 1MHz G1 GROUND HANDLE WITH NEGATIVE POLE The patient will need to hold it during the treatment process S3...

Страница 8: ...radio frequency S2 bi polar radio frequency S3 bi polar radio frequency face lifting Different treatment items need different hand pieces The right hand piece will be in a blue circle click the icon...

Страница 9: ...e treatment will be complete 5 The machine and parameter status On the left side of the interface it will show the device status and parameters of current hand piece temperature air pressure etc Devic...

Страница 10: ...rs until the patient feels comfortable 4 S2 is designed to lift up the eye bags and the surrounding skin of the eye through ablations with radio frequency The eye bag tissues will be heated up to 50 8...

Страница 11: ...en stopping the device the operator should stop the pedal first and then move the hand piece to stop the device 2 Except for handle S2 and S3 the patient should hold the negative pole ground handle du...

Страница 12: ...m a world class company Designed and manufactured in the United Kingdom Laser SOS Aesthetics Ltd Unit 3 Burrel Road St Ives Cambs PE27 3LE United Kingdom Tel 44 1480 409962 Fax 44 1480 498860 Laser SO...

Отзывы: