Installing a Converter Box

Wall Mount

Included in Package

1) Converter Box

Description

Quantity

Picture

2) Mounting kit

(M-SURF-MNT-KIT-1)

1

1

Included in Wiring and Mounting Kit

2a) #10-1.5 Sheet Metal Screw

4

A user will also have to provide a Phillips-head screwdriver, a ruler, a level, and a drill capable of creating #10 sized holes 
in your wall. 

2b) #10 Wall Anchors

4

(See Below)

3) Power Cable

1

Содержание SCB-100-000-1

Страница 1: ...er Box SCB 100 000 1 Version Number 1 3 The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com Current as of March 30 2018 Inst...

Страница 2: ...t 9 10 2 Wire Digital Communication and Wiring Information 11 14 Status Panel 15 Troubleshooting 16 17 Warranty 18 For information on how to install and configure SMA SAM or SBD model clocks please co...

Страница 3: ...cautions to avoid injury by potential safety hazards near the point of installation including but not limited to heavy machinery sharp objects hot surfaces or exposed cables carrying an electric curre...

Страница 4: ...152 m 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AW 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 500 599 ft 152 183 m 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 3...

Страница 5: ...t Clocks 0 138A each Feet Meters 10 15 20 25 30 35 Distance feet meters 0 99 ft 0 30 m 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 16AWG 1 31 mm2 14AWG 2 08 mm2 100 199 ft 30 60 m 16AW...

Страница 6: ...ll Mount Included in Package 1 Converter Box Description Quantity Picture 2 Mounting kit M SURF MNT KIT 1 1 1 Included in Wiring and Mounting Kit 2a 10 1 5 Sheet Metal Screw 4 A user will also have to...

Страница 7: ...oles 1 Use a ruler and a level to mark four points on the wall The screws should have a horizontal separation of 5 inches 12 7cm and a vertical separation of 9 and 7 8 inches 25 1cm Installing a Conve...

Страница 8: ...Attach the signal wiring to the input ports and at least one pair of output ports 8 If the Master clock has been connected powered and configured and the converter box is powered and operating normall...

Страница 9: ...talling a Converter Box Rack Mount Included in Package 1 Converter Box Description Quantity Picture 2 Rack Mount Flaps 1 2 A user will also have to provide a Phillips head screwdriver a mounting rack...

Страница 10: ...and at least one pair of output ports 4 Use the rack screws and nuts to attach the converter box to the rack 5 If the Master clock has been connected powered and configured and the converter box is p...

Страница 11: ...lock 24VAC SAM Series Wired Clock 19 White Black White Black Orange Yellow 115VAC or 230VAC 18 Input A Input B A1 B1 C1 A2 B2 C2 Converter Box Converter Box Converter Box Input A Input B 115VAC or 230...

Страница 12: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 12 2 Wire Digital Communication Wiring Information...

Страница 13: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 13 2 Wire Digital Communication Wiring Information...

Страница 14: ...The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA P 1 215 322 6063 F 1 215 322 8498 www sapling inc com 14 2 Wire Digital Communication Wiring Information...

Страница 15: ...on and off A black circle alone indicates that the LED in question is off 1 2 3 4 5 6 7 8 1 OUTPUT LED PAIRS The converter box has three Output LED pairs A B and C Each pair of output LEDs acts as an...

Страница 16: ...uestion is off If the Output LED nearest to the P in OUTPUT remains on and the Output LED nearest to the O remains off then no data is being received by the converter box If the Master Clock was confi...

Страница 17: ...ch If the solid red light reappears check to confirm that the air vent is not blocked and that the converter box has been installed in a room temperature environment If both conditions have been prove...

Страница 18: ...by The Sapling Company Inc To Goods which are altered modified or repaired in any place other than a Sapling Company Inc factory or by persons not expressly authorized or approved in writing by The Sa...

Отзывы: