- 14 -
6 Parameter summary and instructions
Parameter Description
○ —Parameters that can be modified in any state
× —Parameters that cannot be modified in running state
◆
—Actual detection parameters, which cannot be modified
◇
—Manufacturer parameters, which are limited to manufacturer modification, and users are prohibited
Group F0-basic operating parameters
Code
Item
Description
Setting range
Default
Value
Amend
ment
F0.00 Power
Display current power
0.10
~
99.99KW
Model
setting
◆
F0.01
Main controller
software
version
Display the current software version
number
1.00
~
99.99
1.00
◆
F0.02
Running
command
channel
selection
0
:
Panel command channel
1
:
Terminal command channel
2 Communication command channel
0
~
2
0
○
F0.03
Frequency
setting
selection
0
:
Panel potentiometer
1
:
Digital setting 1, panel ▲, ▼ key
adjustment
2
:
Digital setting 2, terminal UP /
DOWN adjustment
3
:
AVI analog setting (0
~
10V)
4
:
Combination setting
5
:
ACI setting (0
~
20mA)
6
:
Communication setting
7
:
Pulse setting
Note: When combination setting
chosen, the combination setting is
selected in F1.15.
0
~
7
0
○
F0.04
Maximum
output
frequency
The maximum output frequency is the
highest frequency that the inverter is
allowed to output, and it is the
benchmark for acceleration and
deceleration settings.
MAX
{
50.0,
【
F0.05
】}~
999.9Hz
50.0H
z
×
F0.05
Upper limit
frequency
The operating frequency cannot exceed
this frequency
MAX{0.1
,
【
F0.06
】
}
~
【
F0.04
】
50.0H
z
×
F0.06
Lower limit
frequency
The operating frequency cannot be
lower than this frequency
0.0
~
Upper
limit
0.0Hz
×