Precautions

CAUTION

Important information

Do not place any containers that
contain liquid on top of the
system.

Doing so may result in system 
malfunction.

Prohibited

Be sure to securely reinstall all
components after cleaning.

Using the unit without the water tank, filter, or
other component securely installed 
may result in system malfunction. 

Required

Install the system indoors, and
use in an environment between
5°C and 30°C.

In a particularly cold environment, the freeze-
prevention function may be 
activated, and the unit may not 
operate even when the power 
switch is turned ON.

Required

Do not install in a location
exposed to dripping water.

Doing so may result in system malfunction.

Prohibited

Do not perform cleaning while the
system is operating.

Doing so may result in electric shock or
injury.

Prohibited

Grasp the power plug when
unplugging the power cord.

When unplugging the power cord, do not
grasp the cord. Instead, be sure to grasp the
power plug at the end of the cord 
and pull out the plug. Unplugging 
the cord incorrectly may result in 
electric shock, short circuit, or fire.

Required

Do not use the system with the
filter removed.

Dust entering into the system may cause
system malfunction.

Required

Avoid installation in high
locations. Install in a flat and
stable location.

Observe this precaution in order to ensure
that the system functions correctly. 
Failure to do so may result in the 
unit tipping over due to earthquake 
or contact by persons.

Required

Do not obstruct the outlet.

Do not obstruct the outlet with a curtain,
towel, or other item.
Doing so may result in system malfunction.

Prohibited

Do not place any items on the
unit.
Do not climb onto the unit.

Doing so may result in system 
malfunction, or in the unit tipping 
over.

Prohibited

Install in a location where there is
little humidity, cigarette smoke,
or other airborne substance.

Select a location for use which is free of humidity, dust,
cigarette smoke, incense smoke, oil smoke 
(oil particles generated by food preparation), 
salt, or ammonia. Failure to do so may result 
in odors or in system malfunction.

Required

Secure space of 10 cm or more at
the left and right sides of the unit.

Also, allow servicing space of 100 cm or
more above and to the front of the unit.
Failure to do so may result in 
system malfunction.

Required

Be sure to use normal tap
(drinking) water.

Never use water from a water purifier, water
from a water heater, alkali ion water, mineral
water, well water, seawater, or other types of
water. These types of water cannot be
electrolyzed and can cause the growth of
mold or bacteria, resulting in odor.

Do not use tap water in regions
where the concentration of
chlorine ions in the tap water is
low, or in regions where the
chlorine concentration is high.

In some regions, the quality of the tap water
prevents the use of this product. For details,
consult with a dealer.

Do not unplug the power cord,
even if the unit will not be used
for a while.

Even when the unit is stopped, cleaning
inside the system is performed automatically.
Check that there is water in the water tank,
and do not unplug the power cord.

Perform regular cleaning.

Follow the instructions under “Cleaning the
System,” in order to clean and maintain the
unit.
If the unit becomes especially dirty, mold may
grow, resulting in odor.

Do not direct the discharged air
directly onto walls or furniture.

Do not allow the discharged air to directly
contact walls or furniture.
It may damage the walls or furniture, resulting
in stains.

Be careful of freezing.

Freezing may result in system malfunction
and damage.

06-289 Virus_Washer-TM  8/31/06  2:19 PM  Page 2

Содержание VW-VF8AG

Страница 1: ...r Do not soak this unit in water or apply water to it Doing so may result in a short circuit and electric shock Do not wet Do not damage the power cord Do not scratch cut modify bend excessively pull on twist or otherwise damage the power cord Damage to the power cord may result in fire or electric shock Prohibited Do not use chlorine based or acidic detergents when cleaning the water tank unit or...

Страница 2: ...t in system malfunction or in the unit tipping over Prohibited Install in a location where there is little humidity cigarette smoke or other airborne substance Select a location for use which is free of humidity dust cigarette smoke incense smoke oil smoke oil particles generated by food preparation salt or ammonia Failure to do so may result in odors or in system malfunction Required Secure space...

Страница 3: ...38 2 Turbo Approx 4 High Approx 6 Standard Approx 9 3 Tip over prevention chain User s Manual Installation Manual 5 30 Sirocco fan 1 1 5 No ground 1 1 1 2 100 115 30 4P 91 96 Turbo 8 High 5 Standard 3 1 Specifications 1 Product Specifications When the fan speed is standard the fan operates intermittently 1 The rated airflow for the standard fan speed is the average airflow during intermittent oper...

Страница 4: ...tance kΩ Temperature C 2 Part Specifications G Fan motor coil resistance G Thermistor characteristics Model name KUE4T 31CPZ Blue Brown 29 91 Resistance Purple Blue 9 00 Ω Ω Yellow Purple 5 81 Yellow Pink 14 96 Intake temperature sensor Electrolyzing unit water temperature sensor 3 Control Specifications Microcomputer control Settings Fan speed select turbo high standard Service functions Alarm di...

Страница 5: ...ROOM THERMISTOR CS CONTROL SWITCH CR1 INDOOR CONTROLLER CR2 FILTER CONTROLLER POW POWER CONTROLLER IND IND LAMP ASSY TERMINAL PLATE CONNECTOR TERMINAL F1 F2 FUSE 2X 3X RY006 AUXILIARY RELAY ELEC TRODE ELECTRODE DESCRIPTION IND LAMP WTH RC TRANS S TRANS P TA DP FS2 IC Q 24VDEN TRANS S TRANS P IC Q 24VDEN FS2 DENKYOKU FS2 DF TH1 TH2 L N L N S R F2 1 1 7 1 2 1 3 6 5 4 3 2 1 1 2 1 2 1 2 1 3 1 3 1 3 1 ...

Отзывы: