![Sanyo VSP-SV2000 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/sanyo/vsp-sv2000/vsp-sv2000_instruction-manual_363613036.webp)
Alarm Settings
External Alarm Sensor Setting
1
Click the [ALARM] button in the main
menu.
The ALARM CONDITIONS SET screen will
be displayed.
2
As an example, click the [CH1] button in
the ALARM SET screen.
The ALARM SET –CH_1– screen will be
displayed.
3
Change the EXTERNAL ALARM setting to
“NC” or “NO”.
•
OFF: No external alarm is set
•
NC: Normal close
•
NO: Normal open
Note:
Change the MOTION DETECTOR setting to
“OFF”.
4
Change the ALARM BUFFERING setting
to “ON”, and then click the [SET] button.
Note:
When you click the [SET] button, a pop-up
window will appear asking you to confirm that
you want to initialize the alarm data.
•
If there is alarm recording data for the
other channels (2 to 4) in memory, click
the [OK] button also.
In this case, the memory will be
initialized, so the recorded images for all
channels will be erased.
•
If you do not want to clear the images for
the current channel, click the [Cancel]
button.
5
Click the [ALARM] button.
The ALARM CONDITIONS SET screen will
be displayed.
6
Click the button for another channel (CH2
to CH4) in the ALARM SET screen.
A screen such as the ALARM SET –CH_2–
screen will be displayed. Repeat the above
steps to make the settings for channel 2,
channel 3 and channel 4 also.
3
4
ID3
English
– 35 –