18
-
3-8. Adjust Specifications
1. Lens Adjustment (Infinity)
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
If readjusting after it has already been adjusted, wait for 15
minutes or more for the unit to cool down first.
Adjustment method:
1. Set a distance of 0.5-1.0 cm between camera lens and
collimator lens (zoom wide position) . Do not touch the
each lens.
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Select “Infinity Cal.” on the LCD “Test”, and click the “Yes”.
5. Lens infinity adjustment value will appear on the screen.
6. Click the OK.
3-6. The adjustment item which in necessary in part exchange
Factory
Cord
Setting
Language
Setting
Reset
Setting
AWB
Adjust-
ment
USB
storage
information
registration
CCD White
Point
Defect
Detect
Adjustment
CCD Black
Point And
White Point
Defect
Detect
Adjustment
In Lighted
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
Lens
Adjust-
ment
(Infinity)
3-7. Updating the firmware
Check the firmware version immediately after the CP1 board has been replaced. If an old version is being used, interfer-
ence and errors in operation may also occur. If an old version is being used, update it with a newer version.
Refer to
3-13. Firmware uploading procedure. (Page 21)
COMPL PWB CP1
COMPL PWB ST1
COMPL PWB ST2
ASSY FPC, CA1
Camera
Collimator
Dsc Calibration
x
OK
Focus Result
PZ_SW_A_B: 956
PZ_SW_B_C: 1058
PZ_SW_C_B: 1037
PZ_BR: 17
PZ_SP: 266
AF_SW: 941
AF_BR: 6
AF_WIDE: 1
AF_MID1: -19
AF_MID2: -37
AF_MID3: -36
AF_TELE: -33
Содержание VPC-X1200BK
Страница 15: ... 15 ST1 board ST2 board CP1 board 2 4 BOARD LOCATION ...
Страница 25: ...25 1 2 3 4 5 6 7 ...
Страница 53: ...Jan 09 SANYO Electric Co Ltd Osaka Japan ...