Adjustment value determination
a1<1023, a2<1023, a3<1023, a4<1023, a5<1023
wc0=128
±
2, wc1=128
±
2, wc2=130
±
40
wnc0=128
±
2, wnc1=128
±
2, wnc2=130
±
40
0<=g<=255
0<=o<=255
1401<ms1<=3600, 801<ms2<=2500, 1251<ms3<=3100,
1201<ms4<=2900
100<=s1<=220, 100<=s2<=220, 100<=s3<=220,
100<=s4<=220, 100<=s5<=220
ms2<ms4<ms3<ms1
s1>s2>s3>s4>s5
Adjustment values other than the above are irrelevant.
4. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
5. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100
±
20 (K)
Luminance: 900
±
20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.
4. After the adjustment is completed, the number of defect
will appear.
Camera
Pattern box
(color viewer)
6. Gyro Sensor Zero Offset Adjustment
Preparation:
POWER switch: ON
Note:
Do not vibrate after turning on the camera.
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “EIS Adj” on the LCD “Test”.
3. After the adjustment is completed, the adjustment value
will appear.
Carry out the adjustment again if NG will display.