![Sanyo VCC-ZM300PA Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/sanyo/vcc-zm300pa/vcc-zm300pa_service-manual_363532003.webp)
– 3 –
2-3. TABLE FOR SERVICING TOOLS
Note
: Adjustment commander relay jig (VHJ-0142) is for 100 V.
2-3-1. Computer screen during adjustment
2-4. Frequency Adjustment (INT)
Adjustment location:
CT202 (CA-2)
Measuring location:
TP202 (CA-2)
Measuring equipment:
Digital multi meter
Subject:
No designation
Adjusting method:
1. Click the adjustment software installed from the personal
computer, and the adjustment window will be displayed.
2. Click the START.
3. Select the TRIG, and select the INT by the
← →
key of a
keyboard.
4. Adjust with CT202 to 6.0 V
±
0.5 V.
2. ADJUSTMENT
2-1. ADJUSTMENT CONDITION
1. Use the 5,100K viewer for the subject.
2. Set the trigger signal of oscilloscope to VIDEO OUT, and
apply H sync unless specified.
3. Connect the video output to a video monitor with an input
impedance of 75
Ω
.
4. Ground test point is TP200 (CA-2).
5. Set the distance from the subject to about 60 cm and adjust
the camera position so that the picture frame size becomes
as shown below when performing the adjustment with the
gray scale chart (ITE gray scale chart/
γ
= 0.45).
2-2. PREPARATION
1. Install the adjustment software (VHJ-0140) in a computer
running the Windows operating system.
2. Use the adjustment commander cable (VHJ-0143) to con-
nect the adjustment commander relay jig (VHJ-0142) and
CN204.
3. Use the adjustment commander relay jig (VHJ-0142) to con-
nect CN204 of side B in the CA-2 board and serial port (RS-
232C) of computer, and then turn on the power for the com-
puter, camera, and the jig.
VIDEO OUTPUT
Ref. No.
Name
Part code
J-1
J-2
J-3
VJ8-0007
VJ8-0009
Color viewer
Gray scale chart
Color bar chart
VJ8-0010
J-4
J-5
J-6
VHJ-0142
VHJ-0140
Adjustment commander relay jig
Calibration software
L: Distance from CS mount to pattern (mm)
H: Pattern height (mm)
f : Lens focal length (standard 12 mm)
h: Height (4.8 mm) of CCD imaging surface
Note
: The video monitor should be an under-scan TV.
L = x f – 12.5 mm
(H + h)
2
H x h
L
CS mount surface
CCD camera
5,100 K viewer
H
Privacy masking chart
AGC
R GAIN
R HUE
B GAIN
B HUE
WDD
L54W Series Adjustment
x
0
0
0
0
0
AUTO
ROM CLEAR
START
END
CLOSE
TRIG
INT
L-L
IRIS 1V
IRIS 3V
LENS T
AUTO
TELE
LENS X
LENS Y
0
0
TELE
POS1
POS2
R
B
STATUS
J-7
VHJ-0143
Adjustment commander cable
Содержание VCC-ZM300PA