2. ADJUSTMENT
2-1. Table for Servicing Tools
1. Calibration software
Download the calibration software from the following URL.
http://www.overseas.sanyo.com/dcamera_service/
Place the DscCalDi.exe file, camapi32.dll file and
QrCodeInfo.dll file together into a folder of your choice.
2. Pattern box
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure. It is used after adjusting the
chroma meter (VJ8-0192) adjust color temperature to 3100
± 20 K and luminosity to 900 ± 20 cd/m
2
. Be careful of han-
dling the lump and its circumference are high temperature
during use and after power off for a while.
2-2. Setup
1. System requirements
Windows 2000 or XP or Vista
IBM® -compatible PC with pentium processor
USB port
2. Video monitor
Connect the video output to a video monitor with an input
impedance of 75 ohms.
2-3. Adjustment Items and Order
1. Timer Quartz Adjustment
2. Lens Adjustment (Infinity)
3. Lens Adjustment (1m)
4. AWB Adjustment
5. CMOS (CCD) White Point Defect Detect Adjustment
6. CMOS (CCD) Black Point And White Point Defect Detect
Adjustment In Lighted
7. Privacy Masking Adjustment
8. Gyro Offset Adjustment
9. Privacy Masking (Mechanism) Adjustment
Note: If the lens, CMOS and board and changing the part, it
is necessary to adjust again. Item 1-9 adjustments should be
carried out in sequence.
2-4. Connecting the camera to the computer
1. It turns on power.
2. Connect the camera’s USB terminal(CN102 CA-2board)
to the computer’ USB connector.
3. Double-click on the DscCalDi.exe.
4. L5DG2 is selected with Model Code.
5. EX (VCC-HD5400P), US (VCC-HD5400) or C (VCC-
HD5400PC) is selected with Factry Mode.
6. PAL (VCC-HD5400P, VCC-HD5400PC) or NTSC (VCC-
HD5400) is selected with Video Mode.
2-4-1. Computer screen during adjustment
2-4-2. Adjustment USB terminal (CN102)
Firmware
QrCode
AWB
Focus
UV Matrix
R Bright
RGB Offset
Tint
B Bright
Gain
Phase
LCD
Calibration
Upload
Initialize
LCD Type
H AFC
Test
VCOMDC
VCOMPP
Cal Data
Cal Mode
OK
OK
EVF
USB storage
Get
Set
VID
Set
PID
Set
Serial
Set
Rev.
Set
Setting
Language
Video Mode
VCO
Factory Code
Backrush pulse :
Set
Get
Model_Code
Ref. No.
Name
Part code
J-1
J-2
J-3
J-4
J-5
J-6
J-7
VJ8-0190
VJ8-0192
VJ8-0191
VJ8-0260
VJ8-0282
Pattern box
Calibration software
Chroma meter
Spare lump (pattern box)
Collimator
Spare lump (collimator)
Siemens star chart
Number
1
1
1
1
1
1
1
CN102
Содержание VCC-HD5400
Страница 10: ... 10 SY 1 board CA 4 board CA 2 board PW 1 board CP 2 board CP 3 board CA 3 board TB 4 board 1 7 BOARD LOCATION ...
Страница 68: ...PRIVACY MASKING CHART ...
Страница 69: ...SIEMENS STAR CHART ...
Страница 70: ...Dec 09 SANYO Electric Co Ltd Osaka Japan ...