– 4 –
3-3. TABLE FOR SERVICING TOOLS
Connect the adjustment jig and camera with commander cable
(VHJ-0126)
3-3-1. Computer screen during adjustment
3-4. Power Voltage Adjustment
Adjustment location: VR401 (CA-4)
Measuring location: TP405 (CA-4)
Measuring equipment: Digital voltmeter
Subject: No designation
Adjusting method:
1. Adjust with VR401 to 5.10
±
0.02 V.
3-5. Sub Carrier Frequency Adjustment
Adjustment location: CT221 (CA-2)
Measuring location: TP221 (CA-2)
Measuring equipment: Frequency counter
Subject: No designation
Adjusting method:
1. Adjust with CT221 to 4433619 Hz
±
10 Hz.
3-6. 28 MHz VCO Voltage ADJUSTMENT
Adjustment location: CT232 (CA-2)
Measuring location: TP232 (CA-2), S3002 (CA-3)
Measuring equipment: Digital voltmeter
3. ADJUSTMENT
3-1. ADJUSTMENT CONDITION
1. Use the viewer for the subject. As for the fixation of the color
mode, shorten TP301 and TP302 (CA-3) with an alligator
clip.
2. Set the trigger signal of oscilloscope to VIDEO OUT, and
apply H sync unless specified.
3. Set each of the S3002 (CA-3) to the all OFF position, S3001
to the DC position and S3003 to the L position.
4. In adjustments without direction to display charts, shield light
with a lens cap to provide dark condition.
5. Connect the video output to a video monitor with an input
impedance of 75
Ω
.
6. Ground test point are TP200 (CA-2) and TP401 (CA-4).
7. Set the distance from the subject to about 60 cm and adjust
the camera position so that the picture frame size becomes
as shown below when performing the adjustment with the
gray scale chart (ITE gray scale chart/
γ
= 0.45).
8. Apply 24 V AC to the 24 V AC terminal on the camera.
(for VCC-4594P)
Apply 12 V DC to the 12 V DC terminal on the camera.
(for VCC-4592P)
3-2. PREPARATION
1. Install the adjustment software (VHJ-0131) in a computer
running the Windows operating system.
2. Use the adjustment tool (VHJ-0127) to connect the camera
to be adjusted to the serial port of the computer, and then
turn on the power for the computer and the camera.
L: Distance from CS mount to pattern (mm)
H: Pattern height (mm)
f : Lens focal length (standard 12 mm)
h: Height (4.8 mm) of CCD imaging surface
Note : The video monitor should be an under-scan TV.
L = x f – 12.5 mm
(H + h)
2
H x h
L
CS mount surface
CCD camera
5,100 K viewer
H
Ref. No.
Name
Part code
J-1
J-2
J-3
VHJ-0126
VHJ-0131
Commander cable
Adjustment jig
Calibration software
VHJ-0127
Commander cable (VHJ-0126)
AGC
R GAIN
R HUE
B GAIN
B HUE
WDD
L53Z Series Adjustment
x
0
0
0
0
0
AUTO
MOTOR
CHECK
STATUS
START
End
Close
ROM CORRECTION
FILE NAME
VIDEO OUTPUT
Содержание VCC-4592P
Страница 19: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CA 1 CIRCUIT ...
Страница 22: ......
Страница 23: ...CA 2 CIRCUIT ...
Страница 25: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CA 4 CIRCUIT VCC 4592P ONLY ...
Страница 26: ...A B C D E F G H I J K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CA 4 CIRCUIT VCC 4594P ONLY ...
Страница 31: ...Jun 01 1200 MI Printed in Japan SANYO Electric Co Ltd Osaka Japan ...