CONNECTIONS
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately.
1
Make the video signal connection between the camera and the monitor or time lapse VCR.
2
Connect an AC 24 V power source to the 24 V AC connectors on the back of the camera.
Insert the plug of this power cord into a wall outlet.
The
POWER
indicator
(A)
will light. Adjust the picture on the monitor using the Brightness and Contrast
controls.
Note:
•
Use a commercially available 24 V AC adaptor. Make sure to use a cable with an earth line (22AWG or
more) to connect to the earth connector.
•
When installing the camera, use metal brackets to fix the AC adaptor. Then attach it firmly using a
metal strap.
Coaxial cable type and maximum length
•
Cable type RG-59U (3C-2V), 250 m maximum.
•
Cable type RG-6U (5C-2V), 500 m maximum.
•
Cable type RG-11U (7C-2V), 600 m maximum.
CAUTION:
•
The RG-59U type cable should not be run through electrical conduits or through the air.
•
Using CCTV/Video-grade coaxial cable.
(Video signal connections)
: VIDEO IN
: VIDEO OUT
(A)
1
L53S4/XE GB 1999, 6, 16
8