SETTINGS
The switches settings illustrated
are the factory default settings.
A:Line phase adjustment
When using a camera switcher to connect
2 cameras or more to one monitor, there
may be a vertical roll of the images when
switched. In such a case, set as described
below.
1
Set the
SYNC
switch to the
L-L
position.
2
Switch the display on the monitor from
camera 1 to camera 2.
Adjust the
LINE PHASE
volume on
camera 2 until the vertical roll of the
image stops.
If more than two cameras are used,
please repeat this procedure for all the
cameras.
CAUTION:
If the vertical roll cannot be corrected by
setting the
LINE PHASE
volume on camera
2, try setting the
LINE PHASE
volume on
camera 1. If it still cannot be corrected,
please check that the polarity of the power
cords of all connected devices is correct.
The vertical roll can also be adjusted using
an oscilloscope.
1
Set the
SYNC
switch to the
L-L
position.
2
Connect the video signal, for camera 1
and camera 2, output from the camera
switcher, to the oscilloscope.
3
Using the
LINE PHASE
volume on both
cameras, adjust to eliminate the phase
difference (
L3
) between the signal from
camera 1 (
L1
) and the one from
camera 2 (
L2
).
If more than two cameras are used,
please repeat this procedure for all the
cameras.
Vertical sync signal
V
Camera 1
Camera 2
L3
L2
L1
L-L
INT
S
Y
N
C
R
B
VR403 VR402
W
B
ON
OFF
ON
A
M
EI
BLC
L
E
V
E
L
DC
VIDEO
A. I.
LENS
L
H
VR401
L-L
INT
A: Line phase