– 11 –
REC button, TRACKING
buttons, EJECT button
Adj. Condition
TP101(VIDEO
OUT terminal)
TP183 (SW-P)
6.5 H
±
0.5 H
Notes :
• Set the REC/PLAY SPEED button to indicator panel to the
3H (3 hours) mode.
• Self-recoding means “Record any broadcasting or video
signal and play back the just-recorded portion”.
1. Play back the alignment tape. Press the TRACKING buttons
(+) and (–) simultaneously. (TRACKING center position)
2. Press the REC button three times within 10 seconds after
the display is shown. All three presses must be carried out
within 3 seconds. For the third time, press the REC button
more than 0.5 seconds as shown in Fig. 2-1-2.
3. The automatic adjustment mode is set, the numerals of
Indicator display “P 0 : 00” changes automatically and the
unit stops at the point the adjustment value becomes
approx. 6.5 H.
4. In the same adjustment mode, trigger at the edge of the
RF SW pulse, and check that the front edge of the V sync
signal from the fall edge of the RF SW pulse is delayed by
6.5 H
±
0.5 H as shown in Fig. 2-1-3. If it is not 6.5 H
±
0.5
H, manually perform fine adjustments for the TRACKING
buttons (+) or (–) to satisfy the specification.
5. After completing adjustments, press the EJECT button (more
than 1 second) and check the Indicator shows “P – –” at
this time.
Note : Repeat steps 1 to 4 if the adjustment takes more then
20 seconds.
2-1-3. SWITCHING POSITION ADJ.
Measuring Point Measuring Equipment Adj. Condition
Oscilloscope
PLAY (3H) mode
Alignment tape
VHJ-0009
Adj. Condition
Start of play
back display
REC button
ON
OFF
within
10 sec.
within
2 sec.
more
then
0.5
sec.
adjusting
period 10 sec.
Fig. 2-1-2
Fig. 2-1-3
T=6.5H 0.5H
0.5H
1H
Front edge of
vertical sync signal
RF.SW.PULSE
Fall
–
Adj. Value
Adj. Condition
Self-recording
(SP) mode, PLAY
mode, Blank tape
Adj. Location
REC button
TRACKING buttons
EJECT button
Picture of
monitor TV
2-1-4. F. SLOW TRACKING CONFIRM AND ADJ.
Measuring Point Measuring Equipment
Color bar generator
(Monoscope pattern
signal), Monitor TV
1. Insert blank VHS cassette tape and record monoscope pat-
tern on the 3H mode.
2. Play back the self-recorded tape and then set the VCR in
the STILL mode.
3. Change to F. Slow play back mode by pressing REC button
3 times. These 3-push must be done within 3 seconds, and
last push must be kept pressed for 0.5 seconds.
4. Set the tracking control position to the center by pressing
TRACKING (+) and (–) buttons simultaneously, and con-
firm the absence of noise in the slow playback image on
the monitor screen at this centered tracking position. Start-
ing from this centered tracking position, push the (+) and
(–) buttons and confirm that no noise appears before the
fifth push in either direction.
If noise appears before the fifth push, fine-tune with the
front tracking adjustment button so that no noise appears
before the fifth push, then press the EJECT button to make
this point the new tracking center. (When pressing the
EJECT button to enter this new tracking center, the track-
ing should be displayed.)
The FLD counter readout changes to “P – –” for approxi-
mately 1 second in order to confirm that data has been
entered.
3