background image

15

EG

Air Clean Filter 

The air clean filter removes dust and dirt from the air, and reduces

odors and smoke from tobacco.

How to install the air clean filter

The air clean filter needs to be installed behind the anti-mold filter.

1.

Remove the anti-mold filter.

2.

Install the air clean filter in the position shown in the figure.

3.

Remount the anti-mold filter.

How to clean the air clean filter

• In general, the filter should be sucked to remove dust in low fan

speed of a vacuum cleaner once every three months.

• If there is heavily grime on the filter, soak the filter in lukewarm

water with neutral detergent diluted 1:500 for 1 to 2 minutes then

wash it.

• Rinse the filter in clean water, then let it dry on the towel in room

temperature.

• Do not bend nor give excessive force onto the air clean filter.

• If the filter surface is heavily blocked with dirt or damaged,

replace it with new one. Purchase a replacement filter at your

local dealer. (model S

Y-22

)

Cleaning the main unit and remote control unit

• Wipe clean using a soft, dry cloth.

• To remove stubborn dirt, moisten a cloth in warm water no hotter

than 40 °C, wring thoroughly, and then wipe.

• The front panel can be removed in order to wash it with water.

TROUBLESHOOTING

If your air conditioner does not work properly, first check the

following points before requesting service. If it still does not work

properly, contact your dealer or service center.

OPERATING RANGE

For Single use:

The air conditioner is operable within the temperature ranges as

listed below:

For Multiple use:

Please refer to “Operating Range” on the sheet attached to the

outdoor unit.

This air clean filter cannot remove
harmful gases or vapors nor ventilate
air in the room. You must open doors
or windows frequently when you use
gas or oil heating appliances.
Otherwise there is a risk of suffocation
in extreme cases.

Air clean filter

NOTE

Trouble

Possible Cause

Remedy

Air conditioner does

not run at all.

1. Power failure.

1. Restore power.

2. Leakage circuit 

breaker tripped.

2. Contact service

center.

3. Line voltage is too 

low.

3. Consult your

electrician or 

dealer.

4. Batteries in remote

control unit have

run down.

4. Replace batteries.

OPERATION lamp

blinks and air 

conditioner does not

operate.

Trouble in system.

Contact service

center.

Compressor runs but

soon stops.

Obstruction in front of

condenser coil.

Remove obstruction.

Poor cooling (or 

heating)

performance.

1. Dirty or clogged air

filter.

1. Clean air filter to 

improve airflow.

2. Heat source or 

many people in 

room.

2. Eliminate heat 

source if possible.

3. Doors and/or 

windows are open.

3. Shut them to keep

the heat (or cold) 

out.

4. Obstacle near air 

intake or air 

discharge port.

4. Remove it to 

ensure good 

airflow.

5. Thermostat is set

too high for cooling

(or too low for

heating).

5. Set the 

temperature lower

(or higher).

6. (Outdoor

temperature is too 

low for heating.)

6. (Consult your

dealer or try to use

another heat 

appliance.)

Clicking sound is 

heard from the air 

conditioner.

In heating or cooling 

operation, any plastic

parts may expand or 

shrink due to a 

sudden temperature

change. In this event,

a clicking sound may

occur.

This is normal, and 

the sound will soon

disappear.

OPERATION lamp

lights but outdoor unit

will not run.

The use of cellular 

phones near the air 

conditioner may

cause disturbance to

its normal operation.

1. Turn off the power

then restart the air 

conditioner after a 

while.

2. Consult your

dealer.

Temperature Indoor air

temperature

Outdoor air

temperature

COOLING Max.

32 °C DB /

23 °C WB

43 °C DB

Min.

19 °C DB /

14 °C WB

–15 °C DB

HEATING

Max.

27 °C DB

24 °C DB /

18 °C WB

Min.

16 °C DB

– DB/ –15 °C WB

OI-003-15-EG

01_SAP-KRV186EH_EN.fm Page 15 We dnesday, February 13, 2008 1:12 PM

Содержание SAP-FDRV126EH

Страница 1: ...ANUAL DE INSTRUCCIONES Acondicionador de aire de dos unidades controlado por invertidor MODE D EMPLOI Climatiseur de type séparé contrôlé par inverseur BEDIENUNGSANLEITUNG Splitsystem Klimagerät mit Inverter Steuerung ISTRUZIONI PER L USO Condizionatore d aria con sistema separato controllato dall invertitore MANUAL DE INSTRUÇÕES Aparelho de ar condicionado do sistema split com inversor controlado...

Страница 2: ...y switching between cooling and heating does not work Then the air conditioner continuously operates under the mode selected at initial operation Hot Start Heating System Right from the start the air is warm and comfortable This system prevents any cold blasts at the beginning while the heat pump is warming up or even defrosting Automatic Restart Function for Power Failure Even when power failure ...

Страница 3: ...ill have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal ...

Страница 4: ...hrough this hose Outdoor Condensing Unit The outdoor unit contains the compressor fan motor heat exchanger coil and other electrical components INDOOR UNIT Air intake Remote control unit Air outlet REMOTE CONTROL receiver This section picks up infrared signals from the remote control unit transmitter OPERATION button When the remote control cannot be used pressing this button enables heating and c...

Страница 5: ...IGHT SETBACK 6 Confirmation of transmission 7 Auto flap indication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation 10 LED CLEAN operation Displayed when setting timer Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when the time display is set to 12 hour tim...

Страница 6: ...the following chart If selected in a cooling or dry operation the flap is set at position 7 in the following chart The airflow direction can be set manually six positions The flap moves up and down automatically When you press the FLAP button the air flow direction will be changed one by one as follows NOTE CANCEL button LED CLEAN button If this button is pressed during AUTO HEAT DRY COOL or FAN o...

Страница 7: ...he room COOL The air conditioner makes the room cooler FAN The air conditioner works only as a circulation fan except at M of the S M switch NIGHT SETBACK button For details see 5 Night Setback Mode When you press this button in the HEAT DRY or COOL mode the mark appears in the display and the remote control unit will automatically adjust the set temperature to save energy HIGH POWER button If thi...

Страница 8: ...ehind a curtain or other places where it is covered More than 8 m away from the air conditioner In the path of the air conditioner s airstream Where it may become extremely hot or cold Where it may be subject to electrical or magnetic noise Where there is an obstacle between the remote control unit and air conditioner since a check signal is sent from the remote control unit every 5 minutes MOUNTI...

Страница 9: ... on If the automatic operation settings of the unit do not meet your needs press the setting buttons as described below and change the settings as desired STEP 1 Press the MODE selector button and select the desired mode For heating operation For dehumidifying operation For cooling operation For fan only operation No FAN mode at M of the S M switch on the remote control unit STEP 2 To start the ai...

Страница 10: ... Press the ON OFF operation button STEP 3 Press the FAN SPEED selector button to select the fan speed of your choice or There is no FAN only function at M of the S M switch on the remote control unit STEP 2 STEP 1 STEP 3 NOTE When the night setback mode is selected the air conditioner automatically raises the temperature setting 1 C when 30 minutes have passed after the selection was made and then...

Страница 11: ...se this air conditioner heats a room by drawing in the heat of the outside air heat pump system the heating efficiency will fall off when the outdoor temperature is very low If sufficient heat cannot be obtained with this air conditioner use another heating appliance together with it Defrosting When the outdoor temperature is low frost or ice may form on the heat exchanger coil reducing heating pe...

Страница 12: ...timer operates as if it is turned off Operation Indication 1 Press the CLOCK button once if the time indicator is not flashing The time indication alone flashes 2 Press the Advance Return button until PM 10 30 is displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CLOCK button again This completes the setting of...

Страница 13: ...g keep windows doors and any other openings closed ADJUSTING THE AIRFLOW DIRECTION 1 Horizontal upper and lower grille The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right grasping the points indicated in the figure 2 Vertical only upper grille The vertical airflow can be adjusted by moving the flap with the remote control unit Do not move the fl...

Страница 14: ...Clean it Cleaning Use a vacuum cleaner to remove light dust If there is sticky dust on the filter wash the filter in lukewarm soapy water rinse it in clean water and dry it 1 For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning 2 Do not pour water on the indoor unit to clean it This will damage the internal components and cause an electric shock hazar...

Страница 15: ...ows frequently when you use gas or oil heating appliances Otherwise there is a risk of suffocation in extreme cases Air clean filter NOTE Trouble Possible Cause Remedy Air conditioner does not run at all 1 Power failure 1 Restore power 2 Leakage circuit breaker tripped 2 Contact service center 3 Line voltage is too low 3 Consult your electrician or dealer 4 Batteries in remote control unit have ru...

Страница 16: ...100 End fm Page 100 Thursday September 18 2008 1 49 PM ...

Страница 17: ...101 End fm Page 101 Thursday September 18 2008 1 49 PM ...

Страница 18: ...102 End fm Page 102 Thursday September 18 2008 1 49 PM ...

Страница 19: ...A IST EIN FLUORIERTES TREIBHAUSGAS DAS IM KYOTO PROTOKOLL ENTHALTEN IST UND EIN ERDERWÄRMUNGSPOTENTIAL GWP VON 1975 AUFWEIST D Kompatibilität mit den Anforderungen der Vorschrift 842 EC 2006 Artikel 7 1 NON DISPERDERE R410A NELL ATMOSFERA L R410A È UN GAS FLUORATO CAUSA DI EFFETTO SERRA E COPERTO DAL PROTOCOLLO DI KYOTO CON UN POTENZIALE DI RISCALDAMENTO GLOBALE GWP 1975 I Osservanza delle richies...

Страница 20: ...End fm Page 103 Thursday September 18 2008 1 49 PM ...

Отзывы: