2
2. SPECIFICATIONS
2-1. Unit Specifications
Outdoor Unit
SAP – CMRV3143GJ
Type
4-room multi outdoor unit
Number of connectable indoor units
4
Maximum capacity of connected indoor u
kW
15.4
Maximum capacity of operating indoor units
kW
15.4
Power Source
220–240V ~ 50Hz
220V ~ 60Hz
Voltage rating
230 V
220 V
Performance
Cooling
Cooling
Capacity
kW
9.0
(1.2 - 10.5)
9.0
(1.2 - 10.5)
BTU/h
30,700
30,700
Air circulation (High)
m
3
/h
2,800
2,800
Electrical Rating
Cooling
Cooling
Available voltage range
V
198 ~ 264
198 ~ 242
Running amperes
A
8.8
(Max.15.5)
8.8
(Max.15.5)
Power input
W
1,940
1,940
Power factor
%
96
96
C.O.P.
W/W
4.64
4.64
Starting amperes
A
12.7
12.7
Features
Controls
Microprocessor
Fan speeds
Auto (Hi, Lo)
Compressor
Twin Rotary (DC inverter)
Refrigerant / Amount charged at shipment
g
R410A / 4,000
Refrigerant control
Electric Expansion Valve
Operation sound
Hi
dB-A
53
53
Refrigerant tubing connections
Flare type
Max. allowable tubing length per unit
m
30
Refrigerant
Narrow tube
mm (in.)
6.35(1/4)
×
4
tube diameter
Wide tube
mm (in.)
9.52(3/8)
×
3
mm (in.)
12.7(1/2)
×
1
Dimensions & Weight
Unit dimensions
Height
mm
880
Width
mm
940
Depth
mm
340
Package dimensions
Height
mm
981
Width
mm
1,016
Depth
mm
440
Weight
Net
kg
90
Shipping
kg
92
Shipping volume
m
3
0.439
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2. Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Remarks:
1. The value shown in performance section and electrical rating section above are based on the following unit
combination. For other combination of indoor units, please refer to the "Unit Combination Table" in this manual.
Indoor unts: SAP-KMRV93GJ 4 units
(Outdoor unit: SAP-CMRV3143GJ 1 unit )