2
2. SPECIFICATIONS
2-1. Unit Specifications
Outdoor Unit
SAP – CMRV1923GJH
Type
2-room multi outdoor unit
Number of connectable indoor units
2
Maximum capacity of connected indoor units kW
8.6
Maximum capacity of operating indoor units
kW
8.6
Power Source
220–240V ~ 50Hz
220V ~ 60Hz
Voltage rating
230V
220V
Performance
Cooling
Heating
Cooling
Heating
Capacity
kW
5.6 ( 1.4 - 6.5 )
7.3 ( 1.7 - 8.4 )
5.6 ( 1.4 - 6.5 )
7.3 ( 1.7 - 8.4 )
BTU/h
19,100
24,900
19,100
24,900
Air circulation (High)
m
3
/h
2,400
2,400
Electrical Rating
Cooling
Heating
Cooling
Heating
Available voltage range
V
198 ~ 264
198 ~ 242
Running amperes
A
8.5 (Max.14.5)
9.9 (Max.14.5)
8.5 (Max.14.5)
9.9 (Max.14.5)
Power input
W
1,790
2,110
1,790
2,110
Power factor
%
91
93
91
93
C.O.P.
W/W
3.13
3.46
3.13
3.46
Starting amperes
A
9.9
9.9
Features
Controls
Microprocessor
Fan speeds
Auto (Hi, Lo)
Compressor
Twin Rotary (DC inverter)
Refrigerant / Amount charged at shipment
g
R410A / 2,500
Refrigerant control
Electric Expansion Valve
Operation sound
Hi
dB-A
48
49
48
49
Refrigerant tubing connections
Flare type
Max. allowable tubing length per unit
m
25
Refrigerant
Narrow tube
mm (in.)
6.35(1/4)
×
2
tube diameter
Wide tube
mm (in.)
9.52(3/8)
×
2
Dimensions & Weight
Unit dimensions
Height
mm
730
Width
mm
940
Depth
mm
340
Package dimensions
Height
mm
831
Width
mm
1,016
Depth
mm
440
Weight
Net
kg
69
Shipping
kg
71
Shipping volume
m
3
0.37
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2. Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating : Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
Remarks:
1. The value shown in performance section and electrical rating section above are based on the following unit
combination. For other combination of indoor units, please refer to the “Unit Combination Table” in this manual.
Indoor unts: SAP-KMRV93GJH 2 units
(Outdoor unit: SAP-CMRV-1923GJH 1 unit )
Remarks:
1. The values shown in performance section and electrical rating section above are based on the following unit
combination. For other combination of indoor units, please refer to the “Unit Combination Table” in this manual.
Indoor units :
SAP-KMRV93GJH
2 units
(Outdoor unit :
SAP-CMRV-1923GJH
1 unit)
2. Rating conditions are:
Cooling
:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating
:
Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
Содержание SAP-CMRV1923GJH
Страница 9: ......
Страница 52: ...SANYO Electric Co Ltd Osaka Japan SM700539 MAY 2003 Printed in Japan ...