Содержание SA-126P

Страница 1: ... 2005 Sep 08 DESIGN Tai C S 2005 Sep 08 K Fujinaka 18 Dec 05 A TAI C S 15 Dec 05 1 Pg changed Cover Contents Pg 6 2 Add in last 2 Pages Warranty Card 1 APPROVALS DATE REVISIONS R NO DRAWN REMARKS PART CODE SAMS ONLY 851 6 4119 749 00 0 PART NAME EXPLANATORY BOOKLET Andy P 18 Aug 06 B TAI C S 15 Aug 06 1 Text changed Cover Pg 2 rated value 2 Andy P 28 Feb 08 C TAI C S 28 Feb 08 1 Warranty Card Back...

Страница 2: ...Save These Instructions Cooling only Model SANYO Electric Co Ltd SA 76P SA 96P SA 126P SA 186P Pub OI 85164119749003 S ANYO 2006 INSTRUCTION MANUAL Room Air Conditioner With Warranty Card ...

Страница 3: ......

Страница 4: ...g the unit and keep it for consultation If you still have any difficulties or problems consult your dealer for help CONT E NT Function and working temperature range Technical specifications Operating condition and power requirement Installation Notes for installation Part identification 7 Air conditioner operation Operation tips 10 Caution Care and maintenance When trouble shooting 1 2 3 4 6 8 11 ...

Страница 5: ...temperature dry the room It is convenient for your work study and life It can be widely used in residence shop hotel office library and laboratory and so on Cooling in summer In hot summer Air conditioner can cool down room air by transferring heat out Open storm door to keep the fresh air in the room Exchange fresh air ...

Страница 6: ... Hi Low dB A 450 350 580 0 72 7 400 9 300 Model Current A Function Power supply Refrigerant R22 g Power input kW Indoor Hi Low Cooling capacity KJ h SA 76P Cooling Cooling Width Height Depth Net weight kg Dimension mm 35 Outdoor 230V 60Hz Cooling Cooling SA 126P SA 186P SA 96P 12 600 18 200 1 95 8 5 710 52 47 59 53 65 1 33 5 9 720 50 46 58 54 48 3 3 500 48 45 56 52 0 90 4 2 620 49 43 56 52 36 560 ...

Страница 7: ... 230V 10 The compressor would vibrate violently to damage the refrigerant system when voltage is too high AC 230V Cool mode operation Operating condition Power requirement 1 Outdoor temperature should be in range of 19 to 43 Otherwise it is possible for air conditioner to breakdown 2 Room temperature should be in the range of 19 to 32 3 Room humidity should be lower than 90 Otherwise it is possibl...

Страница 8: ...ermal springs and polluted by sulphurous gas or other special areas please contact the seller before use Avoid a place where is possible for inflammable gas to leak out Avoid other heat sources or direct sun light Avoid a place where is easy for children to touch How to install Choose a location where there are no any obstacle surrounding the unit Prepare the installation hole slightly bigger than...

Страница 9: ...the sticker from the front panel 2 Put the unit into the installation hole When installing the unit it should be slanted down to the back to avoid the enlargement of noise or vibration Slant between 6 10mm Shown at right figure The installation place should be strong enough to avoid the enlargement of noise or vibration 3 Fill up sews in the cabinet with sponge or foam Installation assistance Use ...

Страница 10: ...nd reliably The exclusive circuit must be used But removable socket can t be used because poor contact of it can cause over heat or fire Don t pull the power cord strongly In fixed circuit there must be electricity leakage protection switch and leakage current is less than 30mA Air switch thermal magnetic breaker should be installed in the circuit and its recommended capacity is 10A SA 76P SA 96 P...

Страница 11: ... direction adjustment Vertical airflow direction vane Airflow direction adjustment up and down The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards downwards or straight out 7 ...

Страница 12: ...8 Low fan speed with cooling operation ...

Страница 13: ...7 Air conditioner operation 9 FAN Mode ...

Страница 14: ...ch as possible tokeep the cool Clean the air filter regularly Blackages in the air filter reduce dehumidifying effects Clean at least once every two weeks Ventilate the room occasionally Since windows are kept closed it is a good idea to open them and ventilate the room now and then air in the room Do not overcool the room temperature this is not good for health and waste electricity Adjust the ve...

Страница 15: ...kept at an appropriate temperature Do not use heating apparatuses in the air conditioner s plastic parts melt if exposed to exces sive heat Avoid exposing the body directly to a continuous unidirectional air flow for long periods This is not reconmmended for health reason Always wait at least 3 minutes before switching the air condition on again after you have switched it off during cooling Always...

Страница 16: ...tab on the filter and pull to take out Check earth wire Vacuum cleaner Plug out only after air conditioner stops at all unit in which there are micro computer and circuit plate they must not be touched by water Is it broken or loose Check air inlet and outlet of outdoor unit Let the filter dry thoroughly before reinstalling it Donot 2 Vacuum the filter on the dusty side to remove light dust 3 Wash...

Страница 17: ...r unit For a noise that sound like a shower This is the sound of the dehumidifying water being processed inside the air conditioner unit Condensation occurs when the airflow from the air conditioner cools the warm room air This is to protect the mechanism Wait about three minutes and operation will begin Cool efficiency is not good Foggy air flows out The air conditioner operation is noisy It seem...

Страница 18: ...t with your dealer in the following situations Operation starts or stops abnormally Power fuse or switch often breaks Carelessly splash water or something into air conditioner Electrical lines are much hot or lines cover breaks Other strange situations ...

Страница 19: ......

Страница 20: ...ents and parts after the warranty period SSC will not be liable for damages direct or otherwise arising out of delays on failure in furnishing parts or services caused by Acts of God Acts of Government national or local environmental factors labor disputes difficulties or failure of transportation force majeur or other causes beyond its control or for damages resulting from delays in performing th...

Страница 21: ...rranty is valid only on the product purchased and used in the Philippines 5 This Warranty is neither assignable nor transferable NAGA Branch Door No 8 Bldg 1 Puritan Land Devt Corp Roxas Ave Naga City Tel No 054 472 3650 Fax No 054 811 1601 SAN FERNANDO Branch CER HIL Subd Mc Arthur Hi way San Fernando City Pampanga Tel Fax No 045 860 4252 CEBU Branch PO 238 Lopez Jaena St Tipolo Mandaue City Tel ...