6. ELECTRICAL DATA
6-1 Electrical Characteristics
Model
SA – 123AH
COOLING
Fan Motor
Compressor
Complete Unit
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.73
5.4
6.1
Power Input
kW
0.173
1.28
1.45
Full Load Conditions Running Amps.
A
0.73
7.1
7.8
Power Input
kW
0.173
1.69
1.86
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Fan Motor
Compressor
Complete Unit
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.73
5.0
5.7
Power Input
kW
0.173
1.17
1.34
Full Load Conditions Running Amps.
A
0.73
7.8
8.5
Power Input
kW
0.173
1.85
2.02
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.