background image

4

CAUTION:  TO REDUCE THE RISK OF ELECTRIC 

SHOCK, DO NOT REMOVE COVER (OR 
BACK) . NO USER-SERVICEABLE PARTS 
INSIDE EXCEPT LAMP REPLACEMENT .  
REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL .

THIS SYMBOL INDICATES THAT DANGEROUS 

VOLTAGE CONSTITUTING A RISK OF ELECTRIC 

SHOCK IS PRESENT WITHIN THIS UNIT.

THIS SYMBOL INDICATES THAT THERE ARE 

IMPORTANT OPERATING AND MAINTENANCE 

INSTRUCTIONS IN THE OWNER’S MANUAL WITH 

THIS UNIT.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Before operating this projector, read this manual thoroughly 
and operate the projector properly.  
This projector provides many convenient features and 
functions. Operating the projector properly enables you to 
manage those features and maintain it in good condition for 
many years to come.
Improper operation may result in not only shortening the 
product life, but also malfunctions, fire hazard, or other 
accidents.
If your projector seems to operate improperly, read this 
manual again, check operations and cable connections, and 
try the solutions in the “Troubleshooting” section in the back 
of this manual. If the problem still persists, contact the dealer 
where you purchased the projector or the service center.

     

Safety Precaution

 TO  REDUCE THE  RISK  OF  FIRE  OR  ELECTRIC 

SHOCK, DO NOT EXPOSE THIS APPLIANCE TO 
RAIN OR MOISTURE .

– This projector produces intense light from the projection 

lens. Avoid staring directly into the lens as much as possible, 
otherwise eye damage could result. Be especially careful 
that children do not stare directly into the beam.

– Install the projector in a proper position. Otherwise it may 

result in fire hazard.

– Allowing the proper amount of space on the top, sides, 

and rear of the projector cabinet is critical for proper air 
circulation and cooling of the unit. The dimensions shown 
here indicate the minimum space required. If the projector 
is to be built into a compartment or similarly enclosed, these 
minimum distances must be maintained. 

– Do not cover the ventilation slot on the projector. Heat build-

up can reduce the service life of your projector, and can also 
be dangerous.

– If the projector is unused for an extended time, unplug the 

projector from the power outlet.

1.5' (50 cm)

  3' (1 m)

1.5' (50 cm)

1.5' (50 cm)

SIDE and TOP

REAR

READ AND KEEP THIS OWNER’S MANUAL FOR LATER 
USE .

NOTE: 

This symbol and recycle system are applied to EU 
countries only and not to the countries in the other area 
of the world.

Your SANYO product is designed and 
manufactured with high quality materials 
and components which can be recycled 
and reused.

This symbol means that electrical and 
electronic equipment, at their end-of-life, 
should be disposed of separately from 
your household waste.

Please dispose of this equipment at your 

local community waste collection/recycling centre.
In the European Union there are separate collection 
systems for used electrical and electronic products.

Please help us to conserve the environment we live in! 

 

CAUTION ON HANGING FROM THE CEILING

When hanging the projector from the 
ceiling, clean the air intake vents, air filters, 
and the top of the projector periodically 
with a vacuum cleaner. If you leave the 
projector unclean for a long time, the 
cooling fans can be clogged with dust, and 
it may cause a breakdown or a disaster.

DO NOT SET THE PROjECTOR IN GREASy, WET, 
OR SMOKy CONDITIONS SUCH AS IN A KITCHEN 
TO PREVENT A BREAKDOWN OR DISASTER . IF THE 
PROjECTOR COMES IN CONTACT WITH OIL OR 
CHEMICALS, IT MAy BECOME DETERIORATED .

To the Owner

CAUTION

Not  for  use  in  a  computer  room  as  defined  in  the 
Standard for the Protection of Electronic Computer/Data 
Processing Equipment, ANSI/NFPA 75. 
Ne  peut  être  utilisé  dans  une  salle  d’ordinateurs  telle 
que  définie  dans  la  norme ANSI/NFPA  75  Standard  for 
Protection  of  Electronic  Computer/Data  Processing 
Equipment. 

 

WARNING:  THIS APPARATUS MUST BE EARTHED.

Содержание PLV-Z3000

Страница 1: ...Multimedia Projector MODEL PLV Z3000 Owner s Manual ...

Страница 2: ...ace required If the projector is to be built into a compartment or similarly enclosed these minimum distances must be maintained Do not cover the ventilation slot on the projector Heat build up can reduce the service life of your projector and can also be dangerous If the projector is unused for an extended time unplug the projector from the power outlet 1 5 50 cm 3 1 m 1 5 50 cm 1 5 50 cm SIDE an...

Страница 3: ...rough cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the projector Do not install the projector near the ventilation duct of air conditioning equipment This projector should be operated only from the type of power source indicated on the marking label If you are not sure of the type of powe...

Страница 4: ...Underwriters Laboratories UL and certified by the Canadian Standard Association CSA AC Power Cord has a grounding type AC line plug This is a safety feature to be sure that the plug will fit into the power outlet Do not try to defeat this safety feature Should you be unable to insert the plug into the outlet contact your electrician GROUND THE SOCKET OUTLET SHOULD BE INSTALLED NEARTHE EQUIPMENT AN...

Страница 5: ...les Keep the exhaust vent at least 3 1 m away from any objects Do not touch a peripheral part of the exhaust vent especially screws and metallic part This area will become hot while the projector is being used Do not put anything on the projector Objects put on the cabinet will not only get damaged but also cause fire hazard by heat Cooling fans are provided to cool down the projector The fan s ru...

Страница 6: ... to the projector Installation NOTE ONTHE POWER CORD AC power cord must meet the requirements of the country where you use the projector Confirm the AC plug type with the chart below and proper AC power cord must be used If the supplied AC power cord does not match your AC outlet contact your sales dealer Projector side AC Outlet side To POWER CORD CONNECTOR on your projector Ground To the AC Outl...

Страница 7: ...MPONENT 2 Connect the component video output signal to these jacks p 16 w S VIDEO Connect the S Video output signal from video equipment to this jack p 16 r SERVICE PORT This jack is used to service the projector r y t HDMI 1 HDMI 2 Connect the HDMI output signal from video equipment to these terminals p 16 Note on the HDMI connector Use the HDMI connector less than the size shown below Otherwise ...

Страница 8: ...ng range pp 44 53 u OK button Execute the item selected or use it to access the submenu items p 20 y POINT ed7 8 buttons Select an item or adjust the setting values in the On Screen Menu r MENU button Open or close the On Screen Menu p 20 q POWER indicator Lights red while the projector is in stand by mode Lights green during operations Blinks red during the cooling off period Blinks green in the ...

Страница 9: ...ted image pp 23 28 7 IMAGE ADJ button Display the Image adj Menu items one at a time and directly adjust the selected items pp 23 28 0 OK button Execute the selected item or access the sub menu items p 20 8 0 FREEZE button Freeze the projected image p 23 9 INFO button Display the input source information p 43 1 To ensure safe operation observe the following precautions Do not bend drop or expose t...

Страница 10: ...iver when pressing any buttons Maximum operating range for the remote control is about 16 4 5 m and 60 degrees in front of the projector 16 4 5 m 30 Remote Control Operating Range Open the battery compartment lid Install new batteries into the compartment Replace the compartment lid 1 2 3 When the batteries of the remote control are replaced the remote control code automatically returns to the ini...

Страница 11: ...Pr Cr COMPONENT Component Use a component cable optional Connecting to Video Equipment Component Component Cable RCA x 3 Note To order the optional cables see page 58 When connecting HDTV equipment to the projector s COMPONENT 1 2 terminals horizontal line noise may be noted only occasionally Then adjust the value of Fine sync The setting can be adjusted from 0 to 31 see page 34 This projector can...

Страница 12: ... HDMI output Connecting to Video Equipment HDMI RGB Scart HDMI Video Output Unplug the power cords of both the projector and external equipment from the AC outlet before connecting the cables Note To order the optional cables see page 58 COMPUTER Computer Monitor Out Computer Analog Use a VGA cable commercially available or a DVI VGA cable commercially available DVI VGA Cable VGA Cable Installatio...

Страница 13: ... the AC power cord Let the projector cool for at least 45 minutes Loosen the screw that secures the lamp cover and then open the lamp cover Loosen the two 2 screws that secure the lamp Pull out the lamp by using the built in handle Replace the lamp with a new one and secure it with the two 2 screws Make sure that the lamp is set properly Put the lamp cover back and secure it with the screw Connect...

Страница 14: ...re are no broken shards or pieces of glass around the projector or coming out from the cooling air circulation holes Any broken shards found should be cleaned up carefully No one should check the inside of the projector except those who are authorized trained technicians and who are familiar with projector service Inappropriate attempts to service the unit by anyone especially those who are not ap...

Страница 15: ...ance Projection Lamp Video Input jacks mini D sub 15 pin x 1 Computer InputTerminal HDMI terminal 19 pin x 2 HDMI InputTerminals 0 to 6 5 Feet Adjustment Power Source AA or LR6 1 5 V ALKALINE Type x 2 Operating Range 16 4 5 m 30 Dimensions 2 13 x 1 04 x 6 81 54 mm x 26 3 mm x 173mm Net Weight 3 4 oz 95 5 g not including batteries Remote Control 480i 480p 575i 575p 720p 1080i and 1080p High Definit...

Отзывы: