Lamp Replacement
How to check Lamp used time
The LAMP REPLACE indicator will light yellow when
the total lamp used time (Corresponding value) reaches
2000 hours. This is to indicate that lamp replacement is
required.
The total lamp used time is calculated by using the be-
low expression,
Total lamp used time =
T
eco
+
T
normal
x 2
T
eco
: used time in the Eco mode
T
normal
: used time in the Normal mode
You can check the lamp used time following to the below
procedure.
1
Press and hold the
POWER ON-OFF
button on the
projector for more than 20 seconds.
2
The projector used time and lamp used time will be
displayed on the screen briefly as follows.
Lamp replacement
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1 Turn off the projector and disconnect the AC cord.
2 Remove 1 screw with a screwdriver and remove the lamp cover.
3 Loosen 2 screws and pull out the lamp assembly by grasping the
handle.
4 Replace the lamp with a new one and tighten the 2 screws back into
position. Make sure that the lamp is set properly. Replace the lamp
cover and tighten the screw.
5 Connect the AC cord to the projector and turn on.
6 Reset the lamp replacement counter, see below explanation.
Note
- The projector cannot be turned-on with lamp cover removed, because
when the lamp cover is removed, the lamp cover switch is also re-
leased to switch off the lamp circuit.
How to reset Lamp Replace Counter
1
Turn the projector on, press the
MENU
button and the
On-Screen Menu will appear. Press the
Point Left/
Right
button to move the red frame pointer to the Set-
ting Menu icon.
2
Press the
Point Down
button to move the red frame
pointer to the Lamp counter reset item and then press
the
SELECT
button. Select "Reset" and press the
SELECT
button. The message "Lamp replace counter
Reset?" is displayed. Move the pointer to [Yes] and
then press the
SELECT
button.
* Refer to owner's manual for further information.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may re-
sult in internal heat build up and short lamp life. We rec-
ommend cleaning the air filter after the projection lamp
is replaced.
Refer to “Air Filter Cleaning”.
Lamp
Lamp Cover
Screw
Screw
Handle
Screw
Counter
Projector
525H
Lamp
Normal 150H
Eco 375H
Corresponding value 675H
Total lamp used time
Projector used time
ORDER REPLACEMENT LAMP
Type No. Service Parts No.
POA-LMP90 610 323 0726
WARNING : TURN OFF THE UV LAMP BEFORE OPENING.
USE UV RADIATION EYE AND SKIN PROTECTION DURING SERVICING.
Содержание PLC-XU86
Страница 50: ... 50 BA7078 Sync Separator IC5301 IC Block Diagrams BA9743 DDC Control IC5651 ...
Страница 51: ... 51 IC Block Diagrams L3E6100D D A S H LCD Driver IC501 IC531 IC561 FA5502 P F Control IC621 ...
Страница 52: ... 52 IC Block Diagrams L3E07072 LCD Driver Gamma Correction IC401 M62398 D A IC3531 ...
Страница 53: ... 53 IC Block Diagrams STR Z2156A Power Switching IC631 NJW1141 Audio Control IC5001 ...
Страница 54: ... 54 uPD64012 Video Decoder IC101 IC Block Diagrams ...
Страница 83: ...MY5 XU8600 83 Mechanical Parts List 83 L11 L08 L12 L16 L04 L17 L10 L06 L03 L05 In the Optical Unit L08 ...
Страница 85: ...MY5 XU8600 85 Mechanical Parts List ...
Страница 86: ... MY5A Nov 2005 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 90: ...Diagrams Drawings MY5 XU8600 ...
Страница 98: ...A10 SCH_MW5A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D E F G H I J K L A B C D E F G H I J K L ...