-24-
Electrical Adjustments
1. Receive the 1 line black/white pattern computer sig-
nal with
Computer2 [RGB]
mode.
2. Enter the service mode.
3. Project only green light component to the screen.
4. Select group no. “
9
”, item no. “
127
” and change data
value to obtain the minimum flicker on the screen.
5. Project only red light component to the screen.
6. Select item no. “
128
” and change data value to
obtain the minimum flicker on the screen.
7. Project only blue light component to the screen.
8. Select item no. “
129
and change data value to obtain
the minimum flicker on the screen.
,
Common Center adjustment
1. Receive the 16-step gray scale computer signal with
Computer2 [RGB]
mode.
2. Enter the service mode, select group no. “
9
” item
no. “
7
” (Red) or “
8
” (Blue), and change Data values
respectively to make a proper white balance.
Confirm that the same white balance is obtained in
video and computer input.
⁄0
White Balance adjustment [PC]
1. Receive the 16-step grey scale computer signal with
Computer2 [RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TPG1
” (+) and
chassis ground (-).
4. Select group no. “
9
”, item no. “
124
” and change data
value to adjust amplitude “a” to be
10.,0
±0.1V.
5. Connect an oscilloscope to test point “
TPR1
” (+) and
chassis ground (-).
6. Select item no. “
125
” and change data value to
adjust amplitude “a” to be
10.0
±0.1V.
7. Connect an oscilloscope to test point “
TPB1
” (+) and
chassis ground (-).
8. Select item no. “
126
” and change data value to
adjust amplitude “a” to be
9.0
±0.1V.
(a)
black level
black level
m
Black Reference adjustment
1. Receive the 16-step grey scale computer signal with
Computer2 [RGB]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TPG1
” (+)
and chassis ground (-).
4. Select group no. “
9
”, item no. “
6
” and change data
value to adjust amplitude “a” to be
1.6
±0.1V.
(a)
white level
white level
.
50% White adjustment [PC]
1. Receive the 16-step grey scale composite signal with
Video [Video]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TPG1
” (+) and
chassis ground (-).
4. Select group no. “
9
”, item no. “
0
” and adjust the
amplitude “a” to be
minimum
by changing the Data
value.
5. Connect an oscilloscope to test point “
TPR1
” (+) and
chassis ground (-).
6. Select item no. “
1
” and adjust the amplitude “a” to be
minimum
by changing the Data value.
7. Connect an oscilloscope to test point “
TPB1
” (+) and
chassis ground (-).
8. Select item no. “
2
” and adjust the amplitude “a” to be
minimum
by changing the Data value.
(a)
White Level
n
Gain adjustment [Video]
Содержание PLC-XU70
Страница 51: ... 51 BA7078 Sync Separator IC5301 IC Block Diagrams BA9743 DDC Control IC5651 ...
Страница 52: ... 52 IC Block Diagrams L3E6100D D A S H LCD Driver IC501 IC531 IC561 FA5502 P F Control IC621 ...
Страница 53: ... 53 IC Block Diagrams L3E07072 LCD Driver Gamma Correction IC401 M62398 D A IC3531 ...
Страница 54: ... 54 IC Block Diagrams STR Z2156A Power Switching IC631 NJW1141 Audio Control IC5001 ...
Страница 55: ... 55 uPD64012 Video Decoder IC101 IC Block Diagrams ...
Страница 75: ...MS5 XU7000 75 Electrical Parts List Key No Part No Description Key No Part No Description ...
Страница 80: ...MS5 XU7000 80 Mechanical Parts List 80 L11 L08 L12 L16 L04 L17 L10 L06 L03 L05 In the Optical Unit ...
Страница 82: ... MS5A Aug 2005 BB 400 Printed in Japan SANYO Electric Co Ltd ...