-27-
Electrical Adjustments
1. Receive the 16-step grey scale computer signal.
2. Set to
COMPUTER
mode.
3. Enter the service mode.
[R-SIGNAL CENTER ADJUSTMENT]
4. Connect a digital voltmeter to test point “
TP25R1
” (+)
and chassis ground (-).
5. Select group no. “
3
”, item no. “
0
” and change data
value to adjust the voltage to be 7.30 ±0.05V.
[G-SIGNAL CENTER ADJUSTMENT]
6. Connect a digital voltmeter to test point “
TP25G1
” (+)
and chassis ground (-).
7. Select group no. “
3
”, item no. “
1
” and change data
value to adjust the voltage to be 7.30 ±0.05V.
[B-SIGNAL CENTER ADJUSTMENT]
8. Connect a digital voltmeter to test point “
TP25B1
” (+)
and chassis ground (-).
9. Select group no. “
3
”, item no. “
2
” and change data
value to adjust the voltage to be 7.30 ±0.05V.
1. Receive the 16-step grey scale computer signal.
2. Set to
COMPUTER
mode.
3. Connect an oscilloscope to test point “TP3551” (+)
and chassis ground (-).
4. Enter the service mode, select group no. “
3
”, item no.
“
7
” and change data value to adjust amplitude “a” to
be 5.5 ±0.1V.
(a)
Signal Center adjustment
NRS adjustment
1. Receive the 16-step grey scale computer signal.
2. Set to
COMPUTER
mode.
3. Enter the service mode.
[R-BLACK ADJUSTMENT]
4. Connect an oscilloscope to test point “
TP25R1
” (+)
and chassis ground (-).
5. Select group no. “
3
”, item no. “
3
” and change data
value to adjust amplitude “a” to be 10.0 ±0.1V.
[R-BLACK ADJUSTMENT-]
6. Connect an oscilloscope to test point “
TP25G1
” (+)
and chassis ground (-).
7. Select group no. “
3
”, item no. “
4
” and change data
value to adjust amplitude “a” to be 10.0 ±0.1V.
[R-BLACK ADJUSTMENT-]
8. Connect an oscilloscope to test point “
TP25B1
” (+)
and chassis ground (-).
9. Select group no. “
3
”, item no. “
5
” and change data
value to adjust amplitude “a” to be 10.0 ±0.1V.
(a)
black level
black level
Black Level adjustment
1. Receive the 16-step grey scale video signal.
2. Set to
VIDEO
mode.
3. Enter the service mode.
[R-PEDESTAL ADJUSTMENT]
4. Connect an oscilloscope to test point “
TP201R
” (+)
and chassis ground (-).
5. Select group no. “
3
”, item no. “
14
” and change data
value to adjust the pedestal level and black level to be
the same level.
[G-PEDESTAL ADJUSTMENT]
6. Connect an oscilloscope to test point “
TP201G
” (+)
and chassis ground (-).
7. Select group no. “
3
”, item no. “
15
” and change data
value to adjust the pedestal level and black level to be
the same level.
[B-PEDESTAL ADJUSTMENT]
8. Connect an oscilloscope to test point “
TP201B
” (+)
and chassis ground (-).
9. Select group no. “
3
”, item no. “
16
” and change data
value to adjust the pedestal level and black level to be
the same level.
Pedestal level = Black level
(a)
Pedestal adjustment
Содержание PLC-XU32
Страница 47: ... 47 IC Block Diagrams AD8183ARU AD8185ARU Selector IC5241 IC5211 BA6287F Motor Drive IC5501 IC5551 ...
Страница 48: ... 48 CXA2101AQ RGB Matrix IC4101 IC Block Diagrams BA7078AF Selector IC6241 ...
Страница 49: ... 49 CXD2064Q Digital Comb Filter IC2101 L3E01031 Level Shift IC3531 IC3561 IC Block Diagrams ...
Страница 51: ... 51 ML60851 USB I F IC9801 M62393 D A IC2571 IC Block Diagrams ...
Страница 52: ... 52 TA1318N AFC Detector IC6171 TB1274AF Video Decoder IC1101 IC Block Diagrams ...
Страница 53: ... 53 FA7612CA PWC Controller IC65A IC671 IC681 IC Block Diagrams STR Z2156 Switching Controller IC631 ...
Страница 81: ...MK8 XU3200 MK8 XU3700 MH8 XU3300 MH8 XU3800 81 46 44 44 46 44 44 Optical Parts List 46 57 56 46 46 ...
Страница 82: ...MK8 XU3200 MK8 XU3700 MH8 XU3300 MH8 XU3800 82 44 44 54 67 Red 68 Green 69 Blue 44 44 44 Optical Parts List ...
Страница 85: ...MK8 XU3200 MK8 XU3700 MH8 XU3300 MH8 XU3800 85 Optical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62 ...
Страница 86: ... MK8A Jul 2002 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Страница 112: ...Diagrams Drawings PLC XU32 XU33 XU37 XU38 2002 Jul ...