Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46
46
41
40
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
60
61
55
54
30-100
1 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
65
64
6
6
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
15
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
0 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
1 Temp B Warning Offset
(Time)
5
0-100
Temp C Warning Offset
(Time)
18
0-100
3 Temp B-A Warning Offset
(Time)
1
0-100
4 Temp C-A Warning Offset
(Time)
1
0-100
5 Factory Mode
For factor use
0
0-1
Group
254
Fan control range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp Temp Senser Control Start/End Temp.
at High
38
38
34
33
0-100
1 High Fan Control Max Temp
43
43
40
38
0-100
High Fan1 Min
Fan voltage value at High (unit: 0.1V)
95
95
115
115
0-55
3 High Fan1 Max
135
135
135
135
0-55
4 High Fan Min
85
85
130
130
0-55
5 High Fan Max
130
130
130
130
0-55
6 High Fan3 Min
75
75
80
80
0-55
7 High Fan3 Max
77
77
90
90
0-55
8 High Fan4 Min
9999
9999
-
9 High Fan4 Max
9999
9999
-
10 Normal Fan Control Min
Temp
Temp Senser Control Start/End Tem.
p at Normal
38
39
35
33
0-100
11 Normal Fan Control Max
Temp
43
43
40
38
0-100
1 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
80
80
105
105
0-55
13 Normal Fan1 Max
15
15
15
15
0-55
14 Normal Fan Min
75
75
100
100
0-55
15 Normal Fan Max
10
10
10
10
0-55
16 Normal Fan3 Min
70
70
75
75
0-55
17 Normal Fan3 Max
75
70
80
80
0-55
18 Normal Fan4 Min
9999
9999
-
19 Normal Fan4 Max
9999
9999
-
0 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.
p at Eco
38
39
35
3
0-100
1 Eco Fan Control Max Temp
4
43
39
38
0-100
Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
60
60
95
95
0-55
3 Eco Fan1 Max
115
115
115
115
0-55
4 Eco Fan Min
70
70
90
90
0-55
5 Eco Fan Max
110
110
110
110
0-55
6 Eco Fan3 Min
53
53
58
58
0-55
7 Eco Fan3 Max
53
53
63
63
0-55
8 Eco Fan4 Min
9999
9999
-
9 Eco Fan4 Max
9999
9999
-
Group
255
Fan Start/cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70
0-55
1 Fan Initial Volt
70
0-55
Fan3 Initial Volt
70
0-55
3 Not used
9999
-
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
130
0-55
5 Fan Cooling Speed
130
0-55
6 Fan3
Cooling Speed
130
0-55
Содержание PLC-XU115
Страница 65: ... 65 IC Block Diagrams FA7701 DDC Control IC5751 AN5870 Signal Switch IC5201 ...
Страница 66: ... 66 IC Block Diagrams FA7711 DC DC Converter IC5801 FA5502 P F Control IC601 ...
Страница 67: ... 67 IC Block Diagrams L3E06150 D A S H LCD Driver IC501 IC531 IC561 HIN202EIB RS 232C Driver IC3801 ...
Страница 68: ... 68 IC Block Diagrams L3E01060 Level Shift IC2501 IC2531 IC2561 L3E07111 LCD Driver Gamma Correction IC401 ...
Страница 69: ... 69 IC Block Diagrams LM4889 Audio Output IC5031 NJW1156 Audio Control IC5001 ...
Страница 70: ... 70 IC Block Diagrams PW190 Scaler IC301 STR Z2156 Power OSC IC651 ...
Страница 71: ... 71 IC Block Diagrams TE7783 Parallel I O Expander IC1802 ...
Страница 106: ...KF3 XU11500 106 Mechanical Parts List 527 528 L13 L09 L01 L17 L06 L18 L12 L08 L05 L07 In the Optical Unit L10 L13 ...
Страница 108: ... KF3AC April 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...
Страница 128: ...A18 PCB_KF3AC NO DATA ...