PLC-XTC50AL Expand Serial Command Functional Specifications
72/76
9.11.23 CR_TESTPAT Command
Command
“CR_TESTPAT” [CR]
Details
Get setting status of Test pattern
Response
Acceptable
“000_%1” [CR]
%1
“COLOR” ---------------------- Color bar is displayed
“GRAD1” ---------------------- 16step(white
→
black) is displayed
“GRAD2” ---------------------- 16step(white
←
black) is displayed
“GRAD3” ---------------------- 16step(white
↓
black) is displayed
“GRAD4” ---------------------- 16step(white
↑
black) is displayed
“WHITE” ---------------------- All white is displayed
“BLACK” ---------------------- All black is displayed
“CROSS” --------------------- Cross is displayed
“OFF” ---------------------------Test pattern display is not displayed
Unacceptable “Error Code” [CR]
9.11.24 CR_FILH Command
Command
“CR_FILH” [CR]
Details
Get Filter used time
Response
Acceptable
“000_%1” [CR]
%1
“00000 - 99999”
Unacceptable “Error Code” [CR]
9.11.25 CR_FILCOND Command
Command
“CR_FILCOND” [CR]
Details
Get status of filter clog
Response
Acceptable
“000_%1” [CR]
%1
“CLOG” = Filter is clogged
“WARN” = Filter is nearly clogged(Warning status)
“CLEAN” = Filter is not clogged
Unacceptable “Error Code” [CR]
9.11.26 CR_FILREPL Command
Command
“CR_FILREPL” [CR]
Details
Get status of Filter cleaning / replacement time
Response
Acceptable
“000_%1” [CR]
%1
“1Y”-------Filter Exchange time is over value of Filter Message.
“1N”--Filter Exchange time is not over value of Filter Message.
Unacceptable “Error Code” [CR]
9.11.27 CR_FILTIMER Command
Command
“CR_FILTIMER” [CR]
Details
Get Filter used time
Response
Acceptable
“000_%1” [CR]
%1
“400” ------------------- 400 hours
“700” ------------------- 700 hours
“1000” ------------------ 1000 hours
“OFF” ------------------ Warning OSD is not displayed
Unacceptable “Error Code” [CR]